OPC Foundation
  • Documents
  • NodeSets
  • Search
8.110 SafetyValveOrFittingType

A safety valve or fitting.

Table 117– SafetyValveOrFittingType Definition

Attribute

Value

BrowseName

SafetyValveOrFittingType

IsAbstract

False

References

NodeClass

BrowseName

DataType /TypeDefinition

Other

Subtype of PipingComponentType

0:HasComponent

Variable

PositionNumberAssignmentClass

0:String0:BaseDataVariableType

O

0:HasComponent

Variable

FlowOutPipingClassCodeAssignmentClass

0:String0:BaseDataVariableType

O

0:HasComponent

Variable

LocationRegistrationNumberAssignmentClass

0:String0:BaseDataVariableType

O

0:HasComponent

Variable

FlowInPipingClassCodeAssignmentClass

0:String0:BaseDataVariableType

O

0:HasComponent

Variable

SetPressureLow

0:Double0:AnalogUnitType

O

0:HasComponent

Variable

SetPressureHigh

0:Double0:AnalogUnitType

O

PositionNumberAssignmentClass– The position number of the SafetyValveOrFitting.

FlowOutPipingClassCodeAssignmentClass– The code of the piping class at the flow out side of SafetyValveOrFitting.

LocationRegistrationNumberAssignmentClass– The location registration number of the SafetyValveOrFitting.

FlowInPipingClassCodeAssignmentClass– The code of the piping class at the flow in side of SafetyValveOrFitting.

SetPressureLow– The low pressure at which the SafetyValveOrFitting is activated.

SetPressureHigh– The high pressure at which the SafetyValveOrFitting is activated.