The WorkMasterID field of the 6:ISA95JobOrderDataType contains the information about the work master (e.g., the cutting tool file). The field ID is an identification of the work master. This should be used to identify a work master across different OPC UA Servers and must be unique in its scope (e.g., company unique).
This specification uses the 0:FileSystem folder to manage (e.g., store/retrieve files) the work master files on the server. To connect the WorkMasterID with the file additional predefined key-value pairs for 6:ISA95WorkMasterDataType.Parameter are defined in Table 20.
Table 20 – Predefined WorkMaster Parameters
ID |
DataType of Value |
Description |
EngineeringUnits |
Subparameters |
LocalPath |
String |
Contains the file path on the OPC UA server. This must be identical with the relative path of the BrowsePath. |
- |
- |
FileNodeId |
0:NodeId |
Contains the NodeId of the object of the file. |
- |
- |
FileFormat |
FileFormatDataType |
Defines the file format of the work master file. This is used to ensure compatibility between the work master and the machine. |
- |
- |
Note: Example of the LocalPath could be “/Directory1/FileA” with the corresponding BrowsePath as (StartingNode “ns=1;s=FileSystem”; RelativePath: “Directory1/FileA”).It is recommended that the local file system also has a directory “../Directory1/FileA”.
Note: A restart may change the NodeId of the file. So it is recommended to check the FileNodeId before using the file in a WorkMaster. If possible, use the LocalPath instead.
Note: The LocalPath must be used in a WorkMaster and the other Parameters are optional.