OPC Foundation
  • Documents
  • NodeSets
  • Search
6.6.3 ConversionLimitEnum

ConversionLimitEnum indicates whether the ServerUnit can be converted. A distinction is made between NO_CONVERSION, LIMITED and UNLIMITED. NO_CONVERSION means that no conversion is allowed (e.g. for statistical values). LIMITED conversion means that either only the conversions mentioned in the AlternativeUnits are to be used or the client requires specific know-how for the conversion. UNLIMITED means the conversion is simple and possible if the client knows the UnitSystem. The enumeration is defined in Table 51.

Table 51 – ConversionLimitEnum Items

Name

Value

Description

NO_CONVERSION

0

No conversion of the value allowed (e.g. statistical value).

LIMITED

1

Conversion only permitted on the basis of the conversions specified by the server, or if the client has the appropriate domain knowledge to perform an independent conversion.

UNLIMITED

2

Conversion on the basis of the specified unit according to the rules of the source system of units (e.g. SI / ISQ) and the coding system (e.g. UCUM) is permitted.

Its representation in the AddressSpace is defined in Table 52.

Table 52 – ConversionLimitEnum Definition

Attribute

Value

BrowseName

ConversionLimitEnum

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of the Enumeration type defined in OPC 10000-5

HasProperty

Variable

EnumStrings

LocalizedText []

PropertyType

Conformance Units

Data Access Alternative Units

Please report errors or issues with the site to webmaster.

Copyright © 2025 - OPC Foundation