The OperationMode variable with the data type ChamberModeEnumeration represents the current operation mode of the chamber.
The data type for the ChamberModeEnumeration is defined in section 9.4.1.
The TimeRemaining variable with the data type Int32 represents the remaining running time of the current process (baking, cooling, cleaning, etc.). 0 is returned if no process running time is intended.
The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.
This variable represents the set value for the chamber temperature.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable represents the set value for the top chamber temperature.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable represents the set value for the bottom chamber temperature.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable represents the set value for the core temperature.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable represents the set value for the temperature of the steam generator.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable represents the actual value of the chamber temperature.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable represents the actual value of the process program time in seconds.
The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.
This variable represents the actual value of the top chamber temperature.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable represents the actual value of the bottom chamber temperature.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable represents the actual value of the core temperature.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable represents the actual value of the temperature of the steam generator.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable represents the set humidity in the chamber.
The EngineeringUnit property of the AnalogItemType has the value rel%. The value for the EURange property is device-specific.
This variable represents the actual humidity in the chamber.
The EngineeringUnit property of the AnalogItemType has the value rel%. The value for the EURange property is device-specific.
This variable is set when all conditions for a program start are satisfied. (Boolean).
This variable is set when the program has completely finished. (Boolean).
This variable is set when the chamber door is open. (Boolean).
This variable represents the current fan speed in percent.
This variable represents the set fan speed in percent.