CombiSteamerParameterType provides information about the state of a combi steamer, the set values and the current actual values.

The CombiSteamerParameterType is formally defined in Table 22.

Table 22 — CombiSteamerParameterType definition

Attribute

Value

BrowseName

CombiSteamerParameterType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

ModellingRule AccessLevel

Subtype of KitchenDeviceParameterType

HasComponent

Variable

CombiSteamerMode

CombiSteamerModeEnumeration

BaseDataVariableType

M, R

HasComponent

Variable

SetTemperature

Float

AnalogItemType

M, R

HasComponent

Variable

ActualTemperatureChamber_<No.>

Float

AnalogItemType

MP, R

HasComponent

Variable

SetProcessTimeProgram

Int32

AnalogItemType

M, R

HasComponent

Variable

TimeRemainingProgram

Int32

AnalogItemType

M, R

HasComponent

Variable

SetInternalCoreTemperature

Float

AnalogItemType

O, R

HasComponent

Variable

ActualInternalCoreTemperature_<No.>

Float

AnalogItemType

OP, R

HasComponent

Variable

SetExternalCoreTemperature

Float

AnalogItemType

O, R

HasComponent

Variable

ActualExternalCoreTemperature_<No.>

Float

AnalogItemType

OP, R

HasComponent

Variable

SpecialCookingMode

SpecialCookingModeEnumeration

BaseDataVariableType

O, R

HasComponent

Variable

SetProcessTimeStep

Int32

AnalogItemType

O, R

HasComponent

Variable

TimeRemainingStep

Int32

AnalogItemType

O, R

HasComponent

Variable

SetHumidity

Int32

AnalogItemType

O, R

HasComponent

Variable

ActualHumidity

Int32

AnalogItemType

O, R

HasComponent

Variable

IsDoorOpen

Boolean

BaseDataVariableType

M, R

HasComponent

Variable

IsEnergySavingActive

Boolean

BaseDataVariableType

O, R

HasComponent

Variable

IsSteamExhaustSystemActive

Boolean

BaseDataVariableType

O, R

HasComponent

Variable

IsLoaActive

Boolean

BaseDataVariableType

O, R

This variable describes the state of the device, e.g. preheating, active, cleaning, etc. The data type for the CombiSteamerModeEnumeration is defined in section 8.4.1.

This variable contains the set temperature to which heating up is to take place and be regulated.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

The numbered variable ActualTemperaturChamber_<No.> contains the current temperature of a cooking chamber. This variable may be used several times (numbered consecutively), depending on the number of cooking chambers that exist.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

This variable describes the set process time of the entire cooking program in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

This variable describes the remaining process time of the entire cooking program in seconds, i.e. of the current and all subsequent cooking steps.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

This variable describes the set core temperature for the internal core temperature sensor.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

The numbered variable ActualInternalCoreTemperature_<No.> contains the current temperature of an internal core temperature sensor. This variable may be used several times (numbered consecutively), depending on the number of internal core temperature sensors that exist.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

This variable describes the set core temperature for the external core temperature sensor, if the sensor exists.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

The numbered variable ActualExternalCoreTemperatur_<No.> contains the current temperature of an external core temperature sensor. This variable may be used several times (numbered consecutively), depending on the number of external core temperature sensors that exist.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

This variable describes additional cooking methods that do not belong to the standard scope of a combi steamer.

The data type for the SpecialCookingModeEnumeration is defined in 8.4.2.

This variable describes the set process time of the current cooking step in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

This variable describes the remaining process time of the current cooking step in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

This variable describes the set humidity in percent.

The EngineeringUnit property of the AnalogItemType has the value %. The value for the EURange property is device-specific.

This variable describes the actual humidity in percent.

The EngineeringUnit property of the AnalogItemType has the value %. The value for the EURange property is device-specific.

This variable describes whether the door is open.

This variable describes whether the energy saving mode is active. The heating power is reduced in this mode.

This variable describes whether the steam extraction is active.

This variable describes whether the device, when connected to a power optimisation system (LOA), has received the release for heating. The value applies only to those devices that are equipped with a LOA connection and are connected.