This variable describes the state of the device, e.g. heating up or frying.
The data type for the FryerModeEnumeration is defined in 6.4.1.
This variable contains the set temperature to which the frying fat is to be heated.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable describes the currently measured frying temperature.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable describes the set cooking time in seconds.
The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.
This variable describes the remaining frying time in seconds.
The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.
This variable describes the state of the signal output. In addition to the on and off states, the "Signal was acknowledged" state is also saved.
The data type for the SignalModeEnumeration is defined in 6.4.2.
This variable describes whether the frying basket is raised.