This data type is an enumeration of the possible operation modes of the ice machine. The enumeration values are defined in Table 71.
Table 71 — StatusEnumeration values
Value |
Description |
INIT_0 |
Commissioning, started manually (switch on) or automatically (after cleaning) |
WATER_PURGE_1 |
Existing water in the tray is flushed out and fresh water is filled for the next cycle |
PRE_CHILL_2 |
Precooling of the evaporator for xx seconds during the initial commissioning |
FREEZE_3 |
The water freezes on the evaporator to form ice |
HARVEST_4 |
Ice is harvested |
BIN_FULL_5 |
The state indicates that the ice container is full and that ice making has been stopped |
CLEAN_6 |
Ice machine is running through the cleaning steps |
OFF_7 |
Ice machine is switched off |
SLEEP_MODE_8 |
Power failure detected, system clock continues to run |
STANDBY_9 |
State after a temperature sensor error |
SAFE_MODE_10 |
Continue with ice making following an error |
WATER_OUTAGE_11 |
State with a lack of water |
HPCO_DELAY_ACTIVE_12 |
Maintenance state when the overpressure switch is activated and no ice is made for xx minutes |
CURTAIN_OPEN_13 |
Curtain was opened because there is an ice slab between the evaporator and the container. |
PRODUCTION_TEST_14 |
Ice machine is in the function test mode (at the manufacturer) |
SAFE_MODE_PRECHILL_15 |
Like the PRE_CHILL_2 state, but after a SAFE_MODE_10 state |
SAFE_MODE_FREEZE_16 |
Like the FREEZE_3 state, but after a SAFE_MODE_10 state |
SAFE_MODE_HARVEST_17 |
Like the HARVEST_4 state, but after a SAFE_MODE_10 state |
SAFE_MODE_FULL_BIN_18 |
Like the BIN_FULL_5 state, but after a SAFE_MODE_10 state |