This data type is an enumeration of the possible operation modes of the ice machine. The enumeration values are defined in Table 71.

Table 71 — StatusEnumeration values

Value

Description

INIT_0

Commissioning, started manually (switch on) or automatically (after cleaning)

WATER_PURGE_1

Existing water in the tray is flushed out and fresh water is filled for the next cycle

PRE_CHILL_2

Precooling of the evaporator for xx seconds during the initial commissioning

FREEZE_3

The water freezes on the evaporator to form ice

HARVEST_4

Ice is harvested

BIN_FULL_5

The state indicates that the ice container is full and that ice making has been stopped

CLEAN_6

Ice machine is running through the cleaning steps

OFF_7

Ice machine is switched off

SLEEP_MODE_8

Power failure detected, system clock continues to run

STANDBY_9

State after a temperature sensor error

SAFE_MODE_10

Continue with ice making following an error

WATER_OUTAGE_11

State with a lack of water

HPCO_DELAY_ACTIVE_12

Maintenance state when the overpressure switch is activated and no ice is made for xx minutes

CURTAIN_OPEN_13

Curtain was opened because there is an ice slab between the evaporator and the container.

PRODUCTION_TEST_14

Ice machine is in the function test mode (at the manufacturer)

SAFE_MODE_PRECHILL_15

Like the PRE_CHILL_2 state, but after a SAFE_MODE_10 state

SAFE_MODE_FREEZE_16

Like the FREEZE_3 state, but after a SAFE_MODE_10 state

SAFE_MODE_HARVEST_17

Like the HARVEST_4 state, but after a SAFE_MODE_10 state

SAFE_MODE_FULL_BIN_18

Like the BIN_FULL_5 state, but after a SAFE_MODE_10 state