The ProductGroup property represents the parent product group.
The ProductType property represents the special product type within a product group.
The specific product model is represented by the Model property of the DeviceType.
Specifies the number of possible washing tank temperatures (this concerns the pre-wash zone). Value range 0 ... 1; 0 means that no module exists.
The numbered variable PreTankTemperatureSetpoint_<No.> contains the current set temperature of a washing tank (pre-wash zone). One temperature per washing tank. This variable may be used several times (numbered consecutively), depending on the number of washing tanks that exist.
The EngineeringUnit property of the AnalalogItemType has the value °C.
Specifies the number of possible washing tank temperatures (this concerns the main washing zone). Value range 0 ... 5; 0 means that no module exists.
The numbered variable MainTankTemperatureSetpoint_<No.> contains the current set temperature of a washing tank (main washing zone). One temperature per washing tank. This variable may be used several times (numbered consecutively), depending on the number of washing tanks that exist.
The EngineeringUnit property of the AnalalogItemType has the value °C.
Specifies the number of possible rinsing temperatures (circulating tank). Value range 0 ... 3; 0 means that no module exists.
The numbered variable PumpedFinalRinseTemperatureSetpoint_<No.> contains the current set temperature of a rinsing tank. One temperature per rinsing tank. This variable may be used several times (numbered consecutively), depending on the number of rinsing tanks that exist.
The EngineeringUnit property of the AnalalogItemType has the value °C.
Specifies the number of possible fresh water rinsing temperatures. Value range 0 ... 3; 0 means that no module exists.
The numbered variable FinalRinseTemperatureSetpoint_<No.> contains the current set temperature of a rinsing tank (fresh water rinsing). One temperature per rinsing tank. This variable may be used several times (numbered consecutively), depending on the number of rinsing tanks that exist.
The EngineeringUnit property of the AnalalogItemType has the value °C.
Specifies the number of possible washing tank temperatures (this concerns the pre-wash zone). Value range 0 ... 1; 0 means that no module exists.
The numbered variable ActualPreTankTemperature_<No.> contains the current actual temperature of a washing tank (pre-wash zone). One temperature per washing tank. This variable may be used several times (numbered consecutively), depending on the number of washing tanks that exist.
The EngineeringUnit property of the AnalalogItemType has the value °C.
Specifies the number of possible washing tank temperatures (this concerns the main washing zone). Value range 0 ... 5; 0 means that no module exists.
The numbered variable ActualMainTankTemperature_<No.> contains the current actual temperature of a washing tank (main washing zone). One temperature per washing tank. This variable may be used several times (numbered consecutively), depending on the number of washing tanks that exist.
The EngineeringUnit property of the AnalalogItemType has the value °C.
Specifies the number of possible fresh water rinsing temperatures (circulation). Value range 0 ... 3; 0 means that no module exists.
The numbered variable ActualPumpedFinalRinseTemperature_<No.> contains the current actual temperature of a rinsing tank (circulation). One temperature per rinsing tank. This variable may be used several times (numbered consecutively), depending on the number of rinsing tanks that exist.
The EngineeringUnit property of the AnalalogItemType has the value °C.
Specifies the number of possible rinsing temperatures (fresh water rinsing). Value range 0 ... 3; 0 means that no module exists.
The numbered variable ActualFinalRinseTemperature_<No.> contains the current actual temperature of a rinsing tank (fresh water rinsing). One temperature per rinsing tank. This variable may be used several times (numbered consecutively), depending on the number of rinsing tanks that exist.
The EngineeringUnit property of the AnalalogItemType has the value °C.
A variable for the Hygiene setpoint. This variable has no unit. The evaluation depends on the hygiene process.
A variable for the actual Hygiene value. This variable has no unit. The evaluation depends on the hygiene process.
A variable that makes the state of the machine available via the ProgramModeEnumeration.
A variable that makes the state of the machine available via the HygieneModeEnumeration.
A variable that makes the state of the machine available via the OperationModeEnumeration.