MultiFunctionPanParameterType provides information about the state of a pot, the set values and the current actual values.

The MultiFunctionPanParameterType is formally defined in Table 37.

Table 37 — MultiFunctionPanParameterType definition

Attribute

Value

BrowseName

MultiFunctionPanParameterType

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

ModellingRule AccessLevel

Subtype of KitchenDeviceParameterType

HasComponent

Variable

MultiFunctionPanMode

MultiFunctionPanModeEnumeration

BaseDataVariableType

M, R

HasComponent

Variable

SpecialFunctionMode

SpecialFunctionModeEnumeration

BaseDataVariableType

O, R

HasComponent

Variable

CookingLevel

Int32

BaseDataVariableType

O, R

HasComponent

Variable

SetTemperature

Float

AnalogItemType

M, R

HasComponent

Variable

ActualTemperatureBottom

Float

AnalogItemType

M, R

HasComponent

Variable

ActualTemperatureCup

Float

AnalogItemType

M, R

HasComponent

Variable

SetProcessTimeProgram

Int32

AnalogItemType

M, R

HasComponent

Variable

TimeRemainingProgram

Int32

AnalogItemType

M, R

HasComponent

Variable

SetCoreTemperature

Float

AnalogItemType

M, R

HasComponent

Variable

ActualCoreTemperature

Float

AnalogItemType

M, R

HasComponent

Variable

ActualPressureAbsolute

Float

AnalogItemType

O, R

HasComponent

Variable

SetProcessTimeStep

Int32

AnalogItemType

O, R

HasComponent

Variable

TimeRemainingStep

Int32

AnalogItemType

O, R

HasComponent

Variable

SetZoneTemperature_<No.>

Float

AnalogItemType

OP, R

HasComponent

Variable

ActualZoneTemperature_<No.>

Float

AnalogItemType

OP, R

HasComponent

Variable

IsLidLocked

Boolean

BaseDataVariableType

O, R

HasComponent

Variable

IsWithPressure

Boolean

BaseDataVariableType

O, R

HasComponent

Variable

IsWithCleaning

Boolean

BaseDataVariableType

O, R

HasComponent

Variable

IsWithTilting

Boolean

BaseDataVariableType

O, R

HasComponent

Variable

IsWithLift

Boolean

BaseDataVariableType

O, R

HasComponent

Variable

IsLidOpen

Boolean

BaseDataVariableType

O, R

ActualPressureAbsolute and IsLidLocked are required for devices with pressure function.

This variable describes the state of the device, e.g. preheating, active, cleaning

The data type for the MultiFunctionPanModeEnumeration is defined in section 12.4.1.

This variable describes special device functions, e.g. pour in water, tilt pot, lift/lower lid.

The data type for the SpecialFunctionModeEnumeration is defined in section 12.4.2.

This variable describes the cook/grill/pressure stage with which the process should run. The cooking process takes place with different control values or pressure presets, depending on the stage.

This variable contains the set temperature to which heating up is to take place.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

This variable describes the currently measured bottom temperature in the pot.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

This variable describes the currently measured cup temperature in the pot.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

This variable describes the set process time of the entire cooking program in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

This variable describes the remaining process time of the entire cooking program in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

This variable describes the set core temperature.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

This variable describes the currently measured core temperature.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

This variable describes the current absolute pressure in the pot.

The EngineeringUnit property of the AnalogItemType has the value mbar. The value for the EURange property is device-specific.

This variable describes the set process time of the current cooking step in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

This variable describes the remaining process time of the current cooking step in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

The numbered variable SetZoneTemperatur_<No.> contains the set temperature of a zone in °C. This variable may be used several times (numbered consecutively), depending on the number of zones that exist.

The value applies only to the MultiFunctionPanMode ZoneGrilling

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

The numbered variable ActualZoneTemperatur_<No.> contains the current temperature of a zone in °C. This variable may be used several times (numbered consecutively), depending on the number of zones that exist.

The value applies only to the MultiFunctionPanMode ZoneGrilling

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

This variable describes whether the lid is locked. The value applies only to devices with a pressure cooking function.

This variable describes whether the device has the equipment for pressure cooking.

This variable describes whether the device is equipped with automatic cleaning.

This variable describes whether the device has an automatic tilting facility.

This variable describes whether the device has a lift.

This variable describes whether the lid is open.