This DataType is a String that represents an arbitrary name given to a location. It can be used to return location denominations in a simple way, independent of complex coordinate structures.

Its representation in the AddressSpace is defined in Table 29.

Table 29 – LocationName Definition

Attributes

Value

BrowseName

LocationName

Subtype of String defined in OPC 10000-5.

This DataType is a String that represents a GPS coordinate as defined by NMEA 0183 v. 4.10.

Its representation in the AddressSpace is defined in Table 30.

Table 30 – NmeaCoordinateString Definition

Attributes

Value

BrowseName

NmeaCoordinateString

Subtype of String defined in OPC 10000-5.

This DataType is a String that represents a code type used for an AutoID Identifier.

Its representation in the AddressSpace is defined in Table 31.

Table 31 – CodeTypeDataType Definition

Attributes

Value

BrowseName

CodeTypeDataType

Subtype of String defined in OPC 10000-5.

The values in the CodeTypeDataType are extensible by individual manufacturers, starting with "CUSTOM:”. Predefined values are defined in Table 32

Table 32 – CodeType Values

Code Type Value

ScanData Value field in union defined in 9.4.2

Data Type

Description

"RAW:BYTES"

ByteString

ByteString

AutoID Device specific raw data

"RAW:STRING"

String

String

AutoID Device specific raw data to be interpreted as string

"EPC"

Epc

ScanDataEpc

EPC binary structure as defined in 9.3.6

“UID”

ByteString

ByteString

AutoID Identifier according to ISO/IEC 18000-3 Mode 3, ISO/IEC 18000-63 and GS1 EPCglobal™.

“GS1”

ByteString

ByteString

Raw data containing application identifiers (AI) and data according to ISO/IEC 15418.

In case of RFID bit 0x17 of PC is not set. PC contains no AFI.

In case of barcode data start with macro 05 according ISO/IEC 15434.

“ASC”

ByteString

ByteString

Raw data containing data identifiers (DI) and data according to ISO/IEC 15418.

In case of RFID bit 0x17 is set. PC contains AFI.

In case of barcode data start with macro 06 according ISO/IEC 15434.

"URI"

String

String

URI, e.g. EPC string value according to "GS1 EPC Tag Data Standard 1.6"

Example ScanData String value: "urn:epc:id:sgtin:0614141.112345.400"

Also usable for other URIs

"CUSTOM:xxx"

ByteString

String

Custom

ByteString

String

BaseDataType

Any custom defined value ("xxx" is a AutoID Device specific substring of arbitrary length).

Transponder as well as optical 2D-Codes are data carrier for information usually displayed in bits and bytes. But the contained information could be organized in a certain structure. How to do this in a norm conforming way is described in the standard ISO/IEC 15434 “Syntax for high capacity ADC Media” (ADC stands for Automatic Data Capture).

The two most prominent data structures in use are following the rules of GS1 and the ASC MH1. They are described in the standard ISO/IEC 15418 (Data Identifier and Application Identifier).

It is the purpose of these international standards to define the syntax for high capacity ADC media (such as transponder or 2D-Codes), in order to enable ADC users to utilize a single mapping utility, regardless of which high capacity ADC media is employed.

The interoperability of different data structures is achieved by the definition of a Message Header and a Format Header. While the Message Header defines the start and the end of the data contained, the Format Header indicates which data format is used.

Below two examples are shown for a GS1 and an ASC data format.

Example GS1

<Macro05>01312345123457GS1012345GS17101231

Interpretation by the Reader

]d1[)>RS05GS0134012345123457GS1012345GS17101231RSEOT

Example ASC MH 10

<Macro06>25PLEABCBQ3DGS1T234567GS14D101231

Interpretation by the Reader

]d1[)>RS06GS 25PLEABCBQ3DGS1T234567GS14D20101231RSEOT

For RFID the data structures are controlled by AFIs (lower 8 bits of PC) when ISO format is used according ISO/IEC 15961-2 and -3. Depending on the AFI different data compression methods may be used. Details are described for example in ISO 17363, 17364, 17365, 17366 and 17367.

This DataType is an enumeration that specifies the status for the AutoID operations like scan, read, write, lock or kill. Its values are defined in Table 33.

Not all status values are usable for all AutoID reader types. The table contains flags to indicate the expected status values for the different reader types.

Table 33 – AutoIdOperationStatusEnumeration Values

Name

Description

OCR

Opt.

RFID

RTLS

SUCCESS_0

Successful operation

X

X

X

X

MISC_ERROR_TOTAL_1

The operation has not been executed in total

X

MISC_ERROR_PARTIAL_2

The operation has been executed only partial

X

PERMISSON_ERROR_3

Password required

X

PASSWORD_ERROR_4

Password is wrong

X

REGION_NOT_FOUND_ERROR_5

Memory region not available for the actual tag

X

OP_NOT_POSSIBLE_ERROR_6

Operation not supported by the actual tag

X

OUT_OF_RANGE_ERROR_7

Addressed memory not available for the actual tag

X

NO_IDENTIFIER_8

The operation cannot be executed because no tag or code was inside the range of the AutoID Device or the tag or code has been moved out of the range during execution

X

X

X

X

MULTIPLE_IDENTIFIERS_9

Multiple tags or codes have been selected, but the command can only be used with a single tag or code

X

X

X

READ_ERROR_10

The tag or code exists and has a valid format, but there was a problem reading the data (e.g. still CRC error after maximum number of retries)

X

X

DECODING_ERROR_11

The (optical) code or plain text has too many failures and cannot be detected

X

X

MATCH_ERROR_12

The code doesn’t match the given target value

X

X

CODE_NOT_SUPPORTED_13

The code format is not supported by the AutoID Device

X

WRITE_ERROR_14

The tag exists, but there was a problem writing the data

X

NOT_SUPPORTED_BY_DEVICE_15

The command or a parameter combination is not supported by the AutoID Device

X

X

X

X

NOT_SUPPORTED_BY_TAG_16

The command or a parameter combination is not supported by the tag

X

DEVICE_NOT_READY_17

The AutoID Device is in a state not ready to execute the command

X

X

X

X

INVALID_CONFIGURATION_18

The AutoID Device configuration is not valid

X

X

X

RF_COMMUNICATION_ERROR_19

This error indicates that there is a general error in the communication between the transponder and the reader

X

X

DEVICE_FAULT_20

The AutoID Device has a hardware fault

X

X

X

X

TAG_HAS_LOW_BATTERY_21

The battery of the (active) tag is low

X

X

Its representation in the AddressSpace is defined in Table 34.

Table 34 – AutoIdOperationStatusEnumeration Definition

Attribute

Value

BrowseName

AutoIdOperationStatusEnumeration

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumValues

0:EnumValueType []

0:PropertyType

This DataType is an enumeration that defines operational states of an AutoID Device. Its values are defined in Table 35.

Table 35 – DeviceStatusEnumeration Values

Name

Description

Idle_0

The AutoID Device is operating normally and ready to accept commands like Scan or ScanStart method calls (whichever are supported).

Error_1

The AutoID Device is not operating normally. An error condition has to be fixed before normal operation is possible.

Scanning_2

The AutoID Device is operating normally and asynchronous scanning (via ScanStart or automatically) is active. It is AutoID Device dependent which method calls other than ScanStop will be accepted in this state.

Busy_3

The AutoID Device is operating normally, but currently busy (e.g. by synchronous calls of other clients) and not able to accept commands like Scan or ScanStart method calls. This state normally is a temporary one.

Its representation in the AddressSpace is defined in Table 36.

Attribute

Value

BrowseName

DeviceStatusEnumeration

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumStrings

0:LocalizedText []

0:PropertyType

Table 36 – DeviceStatusEnumeration Definition

This DataType is an enumeration that defines the format of the location of an object returned by an RTLS device or system. Its values are defined in Table 37.

Table 37 – LocationTypeEnumeration Values

Name

Description

NMEA_0

An NMEA string representing a coordinate as defined in 9.1.2.

LOCAL_1

A local coordinate as defined in 9.3.4

WGS84_2

A lat/lon/alt coordinate as defined in 9.3.16

NAME_3

A name for a location as defined in 9.1.1

Its representation in the AddressSpace is defined in Table 38.

Table 38 – LocationTypeEnumeration Definition

Attribute

Value

BrowseName

LocationTypeEnumeration

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumStrings

0:LocalizedText []

0:PropertyType

This DataType is an enumeration that defines the operational mode of the LockTag Method Its values are defined in Table 39.

Table 39 – RfidLockOperationEnumeration Values

Name

Description

Lock_0

Locks the memory area

Unlock_1

Unlocks the memory area

PermanentLock_2

Locks the memory area irreversible

PermanentUnlock_3

Unlocks the memory area irreversible

Its representation in the AddressSpace is defined in Table 40.

Attribute

Value

BrowseName

RfidLockOperationEnumeration

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumStrings

0:LocalizedText []

0:PropertyType

Table 40 – RfidLockOperationEnumeration Definition

This DataType is an enumeration that defines the memory region that a lock operation affects. Its values are defined in Table 41.

Table 41 – RfidLockRegionEnumeration Values

Name

Description

Kill_0

The kill password

Access_1

The access password

EPC_2

The UII/EPC bank (bank 01)

TID_3

The TID bank (bank 10)

User_4

The user memory bank (bank 11)

Its representation in the AddressSpace is defined in Table 42.

Table 42 – RfidLockRegionEnumeration Definition

Attribute

Value

BrowseName

RfidLockRegionEnumeration

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumStrings

0:LocalizedText []

0:PropertyType

This DataType is an enumeration that defines the type of a password. Its values are defined in Table 43.

Table 43 – RfidPasswordTypeEnumeration Values

Name

Description

Access_0

Access password

Kill_1

Kill password

Read_2

Read password

Write_3

Write password

Its representation in the AddressSpace is defined in Table 44.

Attribute

Value

BrowseName

RfidPasswordTypeEnumeration

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumStrings

0:LocalizedText []

0:PropertyType

Table 44 – RfidPasswordTypeEnumeration Definition

The Stuctured DataTypes in this chapter are formally defined in two different table formats.

One table format has the columns Name, Type and Description for the definition of standard OPC UA structures where all structure elements are mandatory and must be transported between OPC UA Client and Server.

The second table format has the columns Name, Type, Optional and Description for the definition of OPC UA structures with optional structure elements.

The following Figure 14 provides an overview of the Structure DataTypes defined for the AutoID Device access.

image018.png

Figure 14 – Structure DataType overview

This DataType is a structure that defines a pair of RFID antenna ID and antenna name. Its composition is formally defined in Table 45.

Table 45 – AntennaNameIdPair Structure

Name

Type

Description

AntennaNameIdPair

Structure

Subtype of Structure defined in OPC 10000-5.

AntennaId

Int32

ID of the antenna returned in the RfidSighting contained in the RfidScanResult. The RfidSighting is defined in 9.3.13. The RfidScanResult is defined in 9.3.12.

AntennaName

String

Name of the antenna with the AntennaId.

Its representation in the AddressSpace is defined in Table 46.

Table 46 – AntennaNameIdPair Definition

Attribute

Value

BrowseName

AntennaNameIdPair

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of Structure defined in OPC 10000-5.

This DataType is a structure that defines the location of an object in a Cartesian local coordinate system arbitrarily chosen during configuration of an RTLS system. Its composition is formally defined in Table 47.

Table 47 – LocalCoordinate Structure

Name

Type

Description

LocalCoordinate

Structure

Subtype of Structure defined in OPC 10000-5.

X

Double

The X – coordinate of the object’s position in the unit defined by the LengthUnit property of the AutoID Device.

Y

Double

The Y – coordinate of the object’s position in the unit defined by the LengthUnit property of the AutoID Device.

Z

Double

The Z – coordinate of the object’s position in the unit defined by the LengthUnit property of the AutoID Device.

Timestamp

UtcTime

Timestamp in UtcTime

DilutionOfPrecision

Double

DOP is a value for the variance of the measurements delivered by the location system. The calculation of the value depends on the underlying system and is vendor specific. Values should be in accordance with the implementations like in GNSS systems.

UsefulPrecision

Int32

Values for Easting, Northing, and Altitude should be rounded by the clien tapplication to the n-th position after the decimal point.

It specifies the number of useful digits after the decimal place.

Its representation in the AddressSpace is defined in Table 48.

Table 48 – LocalCoordinate Definition

Attribute

Value

BrowseName

LocalCoordinate

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of Structure defined in OPC 10000-5.

This DataType is a structure that defines the position and the size of a code or a plain text within an image (so-called code area, used by OCR and optical code readers). Its composition is formally defined in Table 49.

Table 49 – Position Structure

Name

Type

Description

Position

Structure

Subtype of Structure defined in OPC 10000-5.

PositionX

Int32

X coordinate of the top-left edge of the code area (counting starts on the left side of the image)

PositionY

Int32

Y coordinate of the top-left edge of the code area (counting starts on the top side of the image)

SizeX

Int32

Horizontal size of the code area in pixel

SizeY

Int32

Vertical size of the code area in pixel

Rotation

Int32

The rotation of the code area

Its representation in the AddressSpace is defined in Table 50.

Table 50 – Position Definition

Attribute

Value

BrowseName

Position

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of Structure defined in OPC 10000-5.

This DataType is a structure that defines the structure of the scanned data in Epc_1 format. Its composition is formally defined in Table 51.

Table 51 – ScanDataEpc Structure

Name

Type

Description

Optional

ScanDataEpc

Structure

Subtype of Structure defined in OPC 10000-5.

PC

UInt16

Protocol control information according to ISO/IEC 18000-3 Mode 3, ISO/IEC 18000-63 and GS1 EPCglobal™.

False

UId

ByteString

AutoID Identifier according to ISO/IEC 18000-3 Mode 3, ISO/IEC 18000-63 and GS1 EPCglobal™.

False

XPC_W1

UInt16

Extended protocol control word 1 according to ISO/IEC 18000-3 Mode 3, ISO/IEC 18000-63 and GS1 EPCglobal™.

True

XPC_W2

UInt16

Extended protocol control word 2 according to ISO/IEC 18000-3 Mode 3, ISO/IEC 18000-63 and GS1 EPCglobal™.

True

Its representation in the AddressSpace is defined in Table 52.

Table 52 – ScanDataEpc Definition

Attribute

Value

BrowseName

ScanDataEpc

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of Structure defined in OPC 10000-5.

This DataType is a structure that defines the settings for a scan execution. Its composition is formally defined in Table 53.

Table 53 – ScanSettings Structure

Name

Type

Description

Optional

ScanSettings

Structure

Subtype of Structure defined in OPC 10000-5.

Duration

Duration

Duration of the scan operation in milliseconds. Duration is one of the termination conditions for the scan operation. The value 0 is infinite.

The termination conditions are related to each other. If one of the conditions is fulfilled, the scan operation is stopped.

False

Cycles

Int32

Duration of the scan operation in ‘number of scan cycles’. The parameter Cycles is one of the termination conditions for the scan operation. The value 0 is infinite.

The termination conditions are related to each other. If one of the conditions is fulfilled, the scan operation is stopped.

False

DataAvailable

Boolean

If this value is set to True, the scan operation is completed as soon as scan data is available.

If this value is set to False, only the other termination conditions are used.

False

LocationType

LocationType Enumeration

The requestsd type of the location information returned in the scan results. The LocationTypeEnumeration DataType is defined in 9.2.3.

True

Its representation in the AddressSpace is defined in Table 54.

Attribute

Value

BrowseName

ScanSettings

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of Structure defined in OPC 10000-5.

Table 54 – ScanSettings Definition

This DataType is a structure that defines the results of a scan. Its composition is formally defined in Table 55.

Table 55 – ScanResult Structure

Name

Type

Description

Optional

ScanResult

Structure

Subtype of Structure defined in OPC 10000-5.

CodeType

CodeTypeDataType

Defines the format of the ScanData as string.

The String DataType CodeTypeDataType and the predefined format strings are defined in 9.1.3.

False

ScanData

ScanData

Holds the information about the detected objects e.g. the detected transponders.

The ScanData DataType is defined in 9.4.2.

False

Timestamp

UtcTime

Timestamp of the ScanResult creation.

False

Location

Location

Returns the location of the object detection.

The Location DataType is defined in 9.4.1.

True

The ScanResult Structure representation in the AddressSpace is defined in Table 56.

Table 56 – ScanResult Definition

Attribute

Value

BrowseName

ScanResult

IsAbstract

True

References

NodeClass

BrowseName

DataType

TypeDefinition

IsAbstract

Subtype of Structure defined in OPC 10000-5.

Has Subtype

DataType

OcrScanResult

False

Has Subtype

DataType

OpticalScanResult

False

Has Subtype

DataType

RfidScanResult

False

Has Subtype

DataType

RtlsLocationResult

False

This DataType is a structure that defines the results of an OCR reader device scan. Its composition is formally defined in Table 57.

Table 57 – OcrScanResult Structure

Name

Type

Description

Optional

OcrScanResult

Structure

Subtype of ScanResult defined in 9.3.8.

ImageId

NodeId

NodeId of the original scan image file object used for this scan result. This image file is also available through the Images folder defined in 6.2.3.2.

False

Quality

Byte

Returns the probability of correct decoding.

False

Position

Position

Returns the position of the text within the image

The Position DataType is defined in 9.3.5.

False

Font

String

Returns the font name used for decoding

True

DecodingTime

UtcTime

Returns the required decoding time

True

Its representation in the AddressSpace is defined in Table 58.

Table 58 – OcrScanResult Definition

Attribute

Value

BrowseName

OcrScanResult

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of ScanResult defined in 9.3.8.

This DataType is a structure that defines the results of a scan. Its composition is formally defined in Table 59.

Table 59 – OpticalScanResult Structure

Name

Type

Description

Optional

OpticalScanResult

Structure

Subtype of ScanResult defined in 9.3.8.

Grade

Float

Returns the Grade of the 1D/2D code according to IEC 15415 (2D) and IEC 15416 (1D). The Grade is a value between 0 and 4 where 0 is the worst quality and 4 is the best quality.

True

Position

Position

Returns the position of the text within the image

The Position DataType is defined in 9.3.5.

True

Symbology

String

Type of barcode per ISO/IEC 15424. Example: "]I1".

True

ImageId

NodeId

NodeId of the original scan image file object used for this scan result.

True

Its representation in the AddressSpace is defined in Table 60.

Attribute

Value

BrowseName

OpticalScanResult

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

IsAbstract

Subtype of ScanResult defined in 9.3.8.

Has Subtype

DataType

OpticalVerifierScanResult

False

Table 60 – OpticalScanResult Definition

This DataType is a structure that defines the results of a scan. Its composition is formally defined in Table 61.

Table 61 – OpticalVerifierScanResult Structure

Name

Type

Description

Optional

OpticalVerifierScanResult

Structure

Subtype of OpticalScanResult defined in 9.3.10.

IsoGrade

String

This value contains the ISO grade, the aperture and the wavelength used.

Example content: "2.7/10/660"

With the '2.7' being the grade, the '10' being the measuring aperture that was used for the analysis and the '660' is the wavelength of light used to illuminate the code. If the grade is reported without aperture and wavelength, then it really is quite meaningless (a code measured with an '06' aperture can give a totally different result that one measured with a '20' aperture for instance).

False

RMin

Int16

The minimum reflection value in percent (from a dark bar).

Example: 6

False

SymbolContrast

Int16

The Symbol Contrast value (Rmax – Rmin) in percent.

Example: 41

False

ECMin

Int16

The minimum Edge Contrast value in percent.

Example: 31

False

Modulation

Int16

The modulation (ECmin / SC) value in percent.

Example: 76

False

Defects

Int16

The defects value in percent.

Example: 14

False

Decodability

Int16

The decodability value in percent.

Example: 87

False

Decode

Int16

The decode content value in percent.

Example: 100

False

PrintGain

Int16

The print gain value in percent (-4%).

Example: -4

False

Its representation in the AddressSpace is defined in Table 62.

Table 62 – OpticalVerifierScanResult Definition

Attribute

Value

BrowseName

OpticalVerifierScanResult

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of OpticalScanResult defined in 9.3.10.

This DataType is a structure that defines the results of a RFID reader device scan. Its composition is formally defined in Table 63.

Table 63 – RfidScanResult Structure

Name

Type

Description

RfidScanResult

Structure

Subtype of ScanResult defined in 9.3.8.

Sighting

RfidSighting [ ]

Returns additional information on the RFID-related properties of the scan event as array of RfidSightings.

Each AutoID Identifier can be detected several times during a scan cycle. Each detection of the AutoID Identifier causes an entry into the Sightings array.

The RfidSighting DataType is defined in 9.3.13.

Its representation in the AddressSpace is defined in Table 64.

Attribute

Value

BrowseName

RfidScanResult

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of ScanResult defined in 9.3.8.

Table 64 – RfidScanResult Definition

This DataType is a structure that defines additional RFID-related information of an AutoID Identifier detection during a scan cycle. Its composition is formally defined in Table 65.

Table 65 – RfidSighting Structure

Name

Type

Description

RfidSighting

Structure

Subtype of Structure defined in OPC 10000-5.

Antenna

Int32

Returns the number of the antenna which detects the RFID tag first.

Strength

Int32

Returns the signal strength (RSSI) of the transponder. Higher values indicate a better strength.

Timestamp

UtcTime

Timestamp in UtcTime.

CurrentPowerLevel

Int32

Returns the current power level (unit according to parameter settings)

Its representation in the AddressSpace is defined in Table 66.

Table 66 – RfidSighting Definition

Attribute

Value

BrowseName

RfidSighting

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of Structure defined in OPC 10000-5.

This DataType is a structure that defines the rotation (or heading) of an object relative to the base coordinate system. The format is ‘yaw, pitch, roll’ as defined for aircraft principal axes. Its composition is formally defined in Table 67.

Table 67 – Rotation Structure

Name

Type

Description

Rotation

Structure

Subtype of Structure defined in OPC 10000-5.

Yaw

Double

The yaw of the object, in the unit defined for rotational measurements, e. g. in radians between PI and –PI (or in deg between +180° and -180°). Rotation measured around a vertical axis. Reference (yaw = 0) is the X-axis of the coordinate system

Pitch

Double

The pitch of the object, in the unit defined for rotational measurements, e. g. in radians between PI and –PI (or in deg between +180° and -180°). Rotation measured around a horizontal axis. Reference (pitch = 0) is the direction of the yaw on the horizontal plane of the coordinate system

Roll

Double

The roll of the object, in the unit defined for rotational measurements, e. g. in radians between PI and –PI (or in deg between +180° and -180°). Rotation measured around a horizontal axis pointing in the direction defined by yaw, pitch

Its representation in the AddressSpace is defined in Table 68.

Attribute

Value

BrowseName

Rotation

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of Structure defined in OPC 10000-5.

Table 68 – Rotation Definition

This DataType is a structure that defines the results that an RTLS device or system returns. It extends the ScanResult structure. Its composition is formally defined in Table 69.

The optional Location field defined in the ScanResult structure shall be included in RtlsLocationResults.

Table 69 – RtlsLocationResult Structure

Name

Type

Description

Optional

RtlsLocationResult

Structure

Subtype of ScanResult defined in 9.3.8.

Speed

Double

The current speed above ground of the located object. The unit is defined by the SpeedUnit variable.

True

Heading

Double

The (geographical) direction the located object is moving in on a plane. The unit is defined by the RotationUnit variable, but note that the heading can be different from the rotation of the object.

True

Rotation

Rotation

The rotation of the object identified by the UId as defined in 9.3.14.

True

ReceiveTime

UtcTime

ReceiveTime provides the time the RTLS received the location information from the underlying device.

True

Its representation in the AddressSpace is defined in Table 70.

Table 70 – RtlsLocationResult Definition

Attribute

Value

BrowseName

RtlsLocationResult

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of ScanResult defined in 9.3.8.

This DataType is a structure that defines the georeferenced location of an object on the earth’s surface in latitude, longitude and altitude using the World Geodetic System’s (WGS84) reference frame. Its composition is formally defined in Table 71.

Table 71 – WGS84Coordinate Structure

Name

Type

Description

WGS84Coordinate

Structure

Subtype of Structure defined in OPC 10000-5.

N/S Hemisphere

String

‘N’ or ‘S’ for northern or southern hemisphere

Latitude

Double

Latitude in the unit defined by the GeographicalUnit property of the DeviceLocation Variable of the AutoID Device defined in 6.1.3.12.

E/W Hemisphere

String

‘E’ or ‘W’ for eastern or western hemisphere

Longitude

Double

Longitude in the unit by the GeographicalUnit property of the DeviceLocation Variable of the AutoID Device defined in 6.1.3.12.

Altitude

Double

Altitude in the unit by the GeographicalUnit property of the DeviceLocation Variable of the AutoID Device defined in 6.1.3.12.

Timestamp

UtcTime

Timestamp in UtcTime

DilutionOfPrecision

Double

DOP is a value for the variance of the measurements delivered by the location system. The calculation of the value depends on the underlying system and is vendor specific. Values should be in accordance with the implementations like in GNSS systems.

UsefulPrecisionLatLon

Int32

Values for Latitude and Longitude should be rounded by the client application to the n-th position after the decimal point.

It specifies the number of useful digits after the decimal place.

UsefulPrecisionAlt

Int32

Values for Altitude should be rounded by the client application to the n-th position after the decimal point.

It specifies the number of useful digits after the decimal place.

Its representation in the AddressSpace is defined in Table 72.

Attribute

Value

BrowseName

WGS84Coordinate

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of Structure defined in OPC 10000-5.

Table 72 – WGS84Coordinate Definition

This DataType is a structure that defines the result values of an AutoID Identifier access of an AutoID device. Its composition is formally defined in Table 73.

Table 73 – AccessResult Structure

Name

Type

Description

Optional

AccessResult

Structure

Subtype of Structure defined in OPC 10000-5.

CodeType

CodeTypeDataType

Defines the format of Identifier as string.

The String DataType CodeTypeDataType and the predefined format strings are defined in 9.1.3.

true

Identifier

ScanData

The AutoID identifier (e.g. a code or a transponder) which was accessed by the command.

The ScanData DataType is defined in 9.4.2. When this value exists, the value CodeType must be available too.

true

Timestamp

UtcTime

The point of time the AutoID Identifier was accessed by the command.

true

The AccessResult Structure representation in the AddressSpace is defined in Table 74.

Table 74 – AccessResult Definition

Attribute

Value

BrowseName

AccessResult

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

IsAbstract

Subtype of Structure defined in OPC 10000-5.

Has Subtype

DataType

RfidAccessResult

False

This DataType is a structure that defines the additional result values of a Rfid Transponder access of a Rfid reader device. Its composition is formally defined in Table 75.

Table 75 – RfidAccessResult Structure

Name

Type

Description

Optional

RfidAccessResult

Structure

Subtype of AccessResult defined in 9.3.17.

CodeTypeRWData

CodeTypeDataType

Defines the format of RWData as string.

The String DataType CodeTypeDataType and the predefined format strings are defined in 9.1.3.

true

RWData

ScanData

The user data which was written to / was read from the Rfid Transponder by the command.

The ScanData DataType is defined in 9.4.2. When this value exists, the value CodeType must be available too.

true

Antenna

Int32

The antenna by which the transponder was accessed by the command.

true

CurrentPowerLevel

Int32

The power level with which the transponder was accessed by the command.

true

PC

UInt16

The Protocol Control Word of the transponder accessed by the command.

true

Polarization

String

The Polarization with which the transponder was accessed by the command.

true

Strength

Int32

The Rssi value with which the transponder was accessed by the command.

true

Its representation in the AddressSpace is defined in Table 76.

Table 76 – RfidAccessResult Definition

Attribute

Value

BrowseName

RfidAccessResult

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of AccessResult defined in 9.3.17.

This DataType is a union that defines different types of location values. Its composition is formally defined in Table 77.

Table 77 – Location Union

Name

Type

Description

Location

Union

NMEA

NmeaCoordinateString

The DataType NmeaCoordinateString is defined in 9.1.2.

Local

LocalCoordinate

The DataType LocalCoordinate is defined in 9.3.4.

WGS84

WGS84Coordinate

The DataType WGS84Coordinate is defined in 9.3.16.

Name

LocationName

The DataType LocationName is defined in 9.1.1

Its representation in the AddressSpace is defined in Table 78.

Attribute

Value

BrowseName

Location

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of Union defined in OPC 10000-5.

Table 78 – Location Definition

This DataType is a union that defines the format of the data scanned by the AutoID Device. Its composition is formally defined in Table 79.

Table 79 – ScanData Union

Name

Type

Description

ScanData

Union

ByteString

ByteString

Scanned data in RAW format.

String

String

Scanned data as String.

Epc

ScanDataEpc

Scanned data as ScanDataEpc structure.

Custom

BaseDataType

Vendor specific data structure.

Its representation in the AddressSpace is defined in Table 80.

Attribute

Value

BrowseName

ScanData

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of Union defined in OPC 10000-5.