The RioFaAnalogOutputConfigDataType represents the configuration of an analog RIO Output Channel according to RIO FA.
Table 91 – RioFaAnalogOutputConfigDataType Structure
Name |
Type |
Description |
RioFaAnalogOutputConfigDataType |
structure |
|
SignalType |
RioSignalTypeEnumeration |
Signal Type. |
WireCheckEnabled |
0:Boolean |
True if wire check is active for the channel, otherwise False. |
SupplyVoltageCheckEnabled |
0:Boolean |
True if supply voltage check is active for the channel, otherwise False. |
LoadVoltageCheckEnabled |
0:Boolean |
True if load voltage check is active for the channel, otherwise False. |
SubstitutePolicy |
RioSubstitutePolicyEnumeration |
Substitute value setting of the channel. |
SubstituteValue |
RioAnalogDataType |
Substitute value for the Process Value. |
SubstituteTime |
0:Float |
Time in seconds from the detection of a failure to the application of the SubstitutePolicy. |
Its representation in the AddressSpace is defined in Table 92.
Table 92 – RioFaAnalogOutputConfigDataType Definition
Attribute |
Value |
|||||
BrowseName |
RioFaAnalogOutputConfigDataType |
|||||
IsAbstract |
False |
|||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
|
Subtype of the 0:Structure type defined in OPC 10000-3 |
||||||
Conformance Units |
||||||
PNRIO Channel Objects |