6 OPC UA ObjectTypes ToC Previous Next

6.19 LogbookEvent ToC Previous Next

6.19.9 MachineModuleSpecificationChangeLogType ToC Previous Next index

The MachineModuleSpecificationChange Event is used for logging the changes of Specification object of a MachineModule.

Table 59 – MachineModuleSpecificationChangeLogType Definition

Attribute Value        
BrowseName MachineModuleSpecificationChangeLogType        
IsAbstract False        
References Node Class BrowseName DataType TypeDefinition Modelling Rule
Subtype of LogbookEventType          
HasComponent Object OldSpecification   MachineModuleSpecificationType Mandatory

The MachineModuleSpecificationType ObjectType is defined in Table 20.

The OldSpecifciation component represents the instance of the Information object of the MachineModule before the change.

Previous Next