GoodOutputProducedLogType

When the GoodProductMasterTotal of the Production object of a MachineModule increases its value, the GoodMaterialProducedLogType is fired.
The representation of the GoodOutputProducedLogType ObjectType in the address space is shown in the following table:
Name | Attribute |
---|---|
NodeId | ns=1;i=1030 |
NamespaceUri | http://opcfoundation.org/UA/TMC/ |
BrowseName | GoodOutputProducedLogType |
NodeClass | ObjectType |
IsAbstract | False |
SubtypeOf | LogbookEventType |
The references from the GoodOutputProducedLogType ObjectType Node are shown in the following table:
Reference | NodeClass | BrowseName | DataType | TypeDefinition | ModellingRule |
---|---|---|---|---|---|
HasComponent | Variable | QuantityProduced | Double | MaterialLotType | Optional |
HasComponent | Variable | TotalProduced | Double | MaterialLotType | Mandatory |