8 OPC UA ObjectTypes ToC Previous Next

8.1 FeederModuleType Definition ToC Previous Next

8.1.4 Method SetFeederSpeed ToC Previous Next

Allows to set a new value for the speed of the feeder system. The OPC UA server must check if the value is between the minimal and maximum allowed speed and if the unit is allowed. The signature of this Method is specified below. Table 13 and Table 14 specify the Arguments and AddressSpace representation, respectively.

Signature

SetFeederSpeed(
[in]	Float		FeederSpeed
[in]	EUInformation	EngineeringUnits);

Table 13 – SetFeederSpeed Method Arguments

Argument Description
FeederSpeed The target speed of a feeder system.
EngineeringUnits The unit of the target feeder speed. The server must check the unit.

Table 14 – SetFeederSpeed Method AddressSpace definition

Attribute Value
BrowseName SetFeederSpeed
References NodeClass BrowseName DataType TypeDefinition ModellingRule
0:HasProperty Variable InputArguments Argument[] 0:PropertyType Mandatory

Previous Next