8 OPC UA DataTypes ToC Previous Next

8.6 OfferedFieldbusesOptionSet ToC Previous Next

The OfferedFieldbusesOptionSet defines flags for fieldbuses supported by the manufacturer of a Pump in Table 124.

Table 124 – OfferedFieldbusesOptionSet Values

Value Bit No. Description
Other 0 Additional fieldbuses listed in the AdditionalFieldbuses variable
ARCNET 1 ARCNET
AS_Interface 2 AS-Interface
BACnet_IP 3 BACnet/IP
BACnet_MSTP 4 BACnet/MSTP
Bluetooth 5 Bluetooth
Bluetooth Low Energy 6 Bluetooth Low Energy
CAN 7 CAN
CANopen 8 CANopen
CC_Link 9 CC-Link
ControlNet 10 ControlNet
DALI 11 DALI
DECT ULE 12 DECT ULE
DeviceNet 13 DeviceNet
DMX 14 DMX
KNX 15 KNX
EnOcean 16 EnOcean
EtherCAT 17 EtherCAT
Ethernet_IP 18 Ethernet/IP
Ethernet TCP_IP 19 Ethernet TCP/IP
IEEE1588 20 IEEE1588
GSM 21 GSM
Interbus 22 Interbus
IO_Link 23 IO-Link
HART 24 HART
LON 25 LON
LoRaWAN 26 LoRaWAN
LIN_Bus 27 LIN-Bus
LTE 28 LTE
LTE_M 29 LTE-M
M_Bus 30 M-Bus
Modbus TCP 31 Modbus TCP
Modbus RTU 32 Modbus RTU
MP_Bus 33 MP-Bus
NB_IOT 34 NB-IOT
NFC 35 NFC
OPC UA 36 OPC UA
OPC DA 37 OPC DA
PROFIBUS DP 38 PROFIBUS DP
PROFINET RT 39 PROFINET RT
Powerlink 40 Powerlink
SERCOS 41 SERCOS
SMI 42 SMI
Thread 43 Thread
UMTS 44 UMTS
WIFI 45 WIFI
X2X_Link 46 X2X-Link
VARAN 47 VARAN
ZigBee 48 ZigBee
Z_Wave 49 Z-Wave

Other on Bit 0 is used to indicate that the manufacturer has added specific fieldbuses in the AdditionalFieldbuses Variable.

The OfferedFieldbusesOptionSet representation in the AddressSpace is formally defined in Table 125.

Table 125 – OfferedFieldbusesOptionSet Definition

Attribute Value
BrowseName OfferedFieldbusesOptionSet
IsAbstract False

Subtype of the OptionSet DataType defined in OPC 10000-5

References NodeClass BrowseName DataType TypeDefinition Other
0:HasProperty Variable OptionSetValues 0:LocalizedText[] 0:PropertyType M, RO

Previous Next