10 DeviceZoneType ToC Previous Next

10.22 MouldEvacuationType ToC Previous Next

MouldEvacuationType is an optional component of DeviceZoneType and includes parameters and nodes for mould evacuation.

Table 14 – MouldEvacuationType Definition

Attribute Value        
BrowseName MouldEvacuationType        
IsAbstract False        
References Node Class BrowseName DataType TypeDefinition Other
Subtype of 0:BaseObjectType defined in OPC UA Part 5          
0:HasComponent Method On     M
0:HasComponent Method Off     M
0:HasComponent Variable TemperatureLimit 0:Double 0:AnalogItemType O, RW
0:HasComponent Variable Time 0:Double 0:AnalogItemType O, RW
0:HasComponent Variable Sink 0:UInt16 0:MultiStateValueDiscreteType O, RW
0:HasComponent Variable Mode 0:UInt16 0:MultiStateValueDiscreteType O, RW

10.22.1 On ToC Previous Next

Description: Activate evacuation mode

Signature

On ();