17 TemperatureRiseMonitoringType ToC Previous Next

At maximum controller output, the temperature value must change in a given time by a specified value, otherwise there is an error in the measuring circuit.

Table 21 – TemperatureRiseMonitoringType Definition

Attribute Value        
BrowseName TemperatureRiseMonitoringType        
IsAbstract False        
References Node Class BrowseName DataType TypeDefinition Other
Subtype of 0:BaseObjectType defined in OPC UA Part 5          
0:HasProperty Variable SetValueActive 0:Boolean 0:PropertyType M, RW
0:HasProperty Variable ErrorDetected 0:Boolean 0:PropertyType M, RO
0:HasProperty Variable SupervisionTime 0:Duration 0:PropertyType O, RW
0:HasComponent Variable SetValueTemperatureChange 0:Double 0:AnalogItemType O, RW

17.1 SetValueActive ToC Previous Next

On / Off for the TemperatureRiseMonitoring.

Previous Next