22 MonitoredParameterType ToC Previous Next

The MonitoredParameterType is used for process parameters that are monitored by the client.

readme_files/image022.gif Figure 17 – MonitoredParameterType Overview

Table 126 – MonitoredParameterType Definition

Attribute Value        
BrowseName MonitoredParameterType        
IsAbstract False        
References Node Class BrowseName DataType TypeDefinition Other
Subtype of 0:BaseObjectType defined in OPC UA Part 5          
0:HasComponent Variable ActualValue 0:Double 0:AnalogItemType M, RO
0:HasComponent Variable SetValue 0:Double 0:AnalogItemType O, RW
0:HasComponent Variable SetRampUp 0:Double 0:AnalogItemType O, RO
0:HasComponent Variable SetRampDown 0:Double 0:AnalogItemType O, RO
0:HasComponent Variable MinValue 0:Double 0:AnalogItemType O, RW
0:HasComponent Variable MaxValue 0:Double 0:AnalogItemType O, RW
0:HasComponent Variable UpperTolerance 0:Double 0:AnalogItemType O, RW
0:HasComponent Variable LowerTolerance 0:Double 0:AnalogItemType O, RW
0:HasComponent Variable UpperTolerance2 0:Double 0:AnalogItemType O, RW
0:HasComponent Variable LowerTolerance2 0:Double 0:AnalogItemType O, RW
0:HasComponent Variable Status 0:UInt16 0:MultiStateValueDiscreteType O, RO
0:HasProperty Variable AutomaticMonitoring 0:Boolean 0:PropertyType O, RW
0:HasComponent Variable MonitoringSensitivity 0:UInt16 0:MultiStateValueDiscreteType O, RW
0:HasComponent Variable AlarmSuppression 0:UInt16 0:MultiStateValueDiscreteType O, RW
0:HasComponent Method ResetMonitoring     O
0:HasSubtype ObjectType ControlledParameterType Defined in Clause 23    

22.1 ActualValue ToC Previous Next

Actual value of the monitored parameter (unit given in AnalogItemType).

Previous Next