MonitoredParameterType TOC Previous Next

Used for process parameters that are monitored by the client.

The representation of the MonitoredParameterType ObjectType in the address space is shown in the following table:

Name Attribute
NodeId ns=1;i=1056
NamespaceUri http://opcfoundation.org/UA/PlasticsRubber/GeneralTypes/
BrowseName MonitoredParameterType
NodeClass ObjectType
IsAbstract False
SubtypeOf BaseObjectType

The references from the MonitoredParameterType ObjectType Node are shown in the following table:

Reference NodeClass BrowseName DataType TypeDefinition ModellingRule
HasComponent Variable ActualValue Double AnalogItemType Mandatory
HasComponent Variable AlarmSuppression UInt16 MultiStateValueDiscreteType Optional
HasProperty Variable AutomaticMonitoring Boolean PropertyType Optional
HasComponent Variable LowerTolerance Double AnalogItemType Optional
HasComponent Variable LowerTolerance2 Double AnalogItemType Optional
HasComponent Variable MaxValue Double AnalogItemType Optional
HasComponent Variable MinValue Double AnalogItemType Optional
HasComponent Variable MonitoringSensitivity UInt16 MultiStateValueDiscreteType Optional
HasComponent Method ResetMonitoring     Optional
HasComponent Variable SetRampDown Double AnalogItemType Optional
HasComponent Variable SetRampUp Double AnalogItemType Optional
HasComponent Variable SetValue Double AnalogItemType Optional
HasComponent Variable Status UInt16 MultiStateValueDiscreteType Optional
HasComponent Variable UpperTolerance Double AnalogItemType Optional
HasComponent Variable UpperTolerance2 Double AnalogItemType Optional
HasSubtype ObjectType ControlledParameterType      

ResetMonitoring

Signature

    ResetMonitoring(    );