7 Pelletizer_InterfaceType ToC Previous Next

7.1 Pelletizer_InterfaceType Definition ToC Previous Next

readme_files/image005.gif Figure 1 – Pelletizer_InterfaceType Overview

Table 1 – Pelletizer_InterfaceType Definition

Attribute Value        
BrowseName Pelletizer_InterfaceType        
IsAbstract False        
References Node Class BrowseName DataType TypeDefinition Other
Subtype of 4:ExtrusionDeviceType (defined in OPC 40084-1)          
0:HasComponent Object Drive   3:DriveType M
0:HasProperty Variable PelletizerClosed 0:Boolean 0:PropertyType O, RO
0:HasProperty Variable WaterFlowActive 0:Boolean 0:PropertyType O, RO
0:HasComponent Variable CutGap 0:Double 0:AnalogUnitType O, RO
0:HasComponent Object TemperatureZones   4:ExtrusionTemperatureZonesType O
0:HasComponent Object PressureZones   3:MeasuringDevicesType O
0:HasComponent Object KnifePackage_<Nr>   KnifePackageType OP
0:HasComponent Object DiePlate_<Nr>   DiePlateType OP

The BrowseName of the object instance shall be “Pelletizer_<Manufacturer>_<SerialNumber>”

Example: “Pelletizer_Erema_0123456”.

The instance(s) of Pelletizer_InterfaceType shall be located under the DeviceSet Object of the Server (see OPC UA Part 100).

NOTE: If the OPC UA server is implemented in the control of the pelletizer so only one instance of Pelletizer_InterfaceType will be created. But it is also possible that one OPC UA server is connected to several machine controls as one interface to the MES. In this case several instances of Pelletizer_InterfaceType will be created.

Previous Next