7 Cutter_InterfaceType ToC Previous Next

7.6 CuttingProductType ToC Previous Next

Description of the product to be cut with Id, length, length correction wall thickening and amount of output.

Table 3 – CuttingProductType Definition

Attribute Value        
BrowseName CuttingProductType        
IsAbstract False        
References Node Class BrowseName DataType TypeDefinition Other
Subtype of 0:BaseObjectType defined in OPC UA Part 5          
0: HasProperty Variable Id 0:String 0:PropertyType M, RO
0:HasComponent Variable Length 0:Double 0:AnalogUnitType M, RW
0:HasComponent Variable LengthCorrection 0:Double 0:AnalogUnitType O, RW
0:HasComponent Variable WallThickeningLength 0:Double 0:AnalogUnitType O, RW
0:HasProperty Variable WallThickeningPosition WallThickeningEnumeration 0:PropertyType O, RW
0:HasComponent Variable SetOutput 0:UInt64 0:BaseDataVariableType M, RW
0:HasComponent Variable ActualOutput 0:UInt64 0:BaseDataVariableType M, RO
0:HasComponent Variable TotalOutput 0:UInt64 0:BaseDataVariableType M, RO
0:HasComponent Method ResetOutput     O

The ActualOutput is related to the output during producing one product type and automatically reset when the CuttingProduct is newly started

TotalOutput: Total sum of output

For the wall thickening the length and the position needs to be defined.

Table 4 – WallThickeningEnumeration Definition

Name Value Description
NO 0 No wall thickening
FRONT 1 Wall thickening only at the front of the product
END 2 Wall thickening only at the end of the product
BOTH 3 Wall thickening at both sides of the product

Previous Next