NMT_BootTime_Type TOC Previous Next Specification

Variable Type to represent the POWERLINK Record NMT_BootTime_TYPE.

The representation of the NMT_BootTime_Type VariableType in the address space is shown in the following table:

Name Attribute
NodeId ns=1;i=16
NamespaceUri http://opcfoundation.org/UA/POWERLINK/
BrowseName NMT_BootTime_Type
NodeClass VariableType
DataType Byte
ValueRank -1
IsAbstract False
SubtypeOf PowerlinkRecordType

The references from the NMT_BootTime_Type VariableType Node are shown in the following table:

Reference NodeClass BrowseName DataType TypeDefinition ModellingRule
HasProperty Variable Index UInt16 PropertyType Mandatory
HasComponent Variable MNConfigurationTimeout_U32 UInt32 PowerlinkVariableType Optional
HasComponent Variable MNIdentificationTimeout_U32 UInt32 PowerlinkVariableType Optional
HasComponent Variable MNSoftwareTimeout_U32 UInt32 PowerlinkVariableType Optional
HasComponent Variable MNStartCNTimeout_U32 UInt32 PowerlinkVariableType Optional
HasComponent Variable MNSwitchOverCycleDivider_U32 UInt32 PowerlinkVariableType Optional
HasComponent Variable MNSwitchOverDelay_U32 UInt32 PowerlinkVariableType Optional
HasComponent Variable MNSwitchOverPriority_U32 UInt32 PowerlinkVariableType Optional
HasComponent Variable MNTimeoutPreOp1_U32 UInt32 PowerlinkVariableType Mandatory
HasComponent Variable MNTimeoutPreOp2_U32 UInt32 PowerlinkVariableType Mandatory
HasComponent Variable MNTimeoutReadyToOp_U32 UInt32 PowerlinkVariableType Mandatory
HasComponent Variable MNWaitNotAct_U32 UInt32 PowerlinkVariableType Mandatory
HasComponent Variable MNWaitPreOp1_U32 UInt32 PowerlinkVariableType Optional
HasProperty Variable NumberOfEntries Byte PropertyType Mandatory