EnergyDevicePowerOffType TOC Next Specification

The representation of the EnergyDevicePowerOffType ObjectType in the address space is shown in the following table:

Name Attribute
NodeId ns=1;i=1012
NamespaceUri http://opcfoundation.org/UA/PNEM/
BrowseName EnergyDevicePowerOffType
NodeClass ObjectType
IsAbstract False
SubtypeOf BaseObjectType

The references from the EnergyDevicePowerOffType ObjectType Node are shown in the following table:

Reference NodeClass BrowseName DataType TypeDefinition ModellingRule
HasComponent Variable ModePowerConsumption UInt32 BaseDataVariableType Mandatory
HasComponent Variable RegularTimeToOperate Duration BaseDataVariableType Mandatory
HasComponent Method SwitchOffWOL     Mandatory
HasComponent Variable TimeMinPause Duration BaseDataVariableType Mandatory
HasProperty Variable WOLMagicPacket ByteString PropertyType Mandatory

SwitchOffWOL

Signature

    SwitchOffWOL(        [out] Byte ModeID
        [out] Duration CurrentTimeToDestination
        [out] Duration RegularTimeToOperate
        [out] Duration TimeMinLengthOfStay
        [out] Byte ReturnCode
    );
Argument Description
ModeID ID of the destination energy saving mode (0xFE) if successful, otherwise unchanged.
CurrentTimeToDestination Time needed to reach the energy saving mode if successful, otherwise unchanged.
RegularTimeToOperate Time needed to reach PE_ready_to_operate again if the destination energy saving mode will be regularly terminated if successful, otherwise unchanged.
TimeMinLengthOfStay Time of minimum stay in the destination energy saving mode if successful, otherwise unchanged.
ReturnCode PROFIenergy return code. See Table 11.