8 Type definitions for Combi Steamer

8.2 CombiSteamerParameterType

8.2.3 Description of the object type

8.2.3.1 CombiSteamerMode variable 
This variable describes the state of the device, e.g. preheating, active, cleaning, etc. The data type for the CombiSteamerModeEnumeration is defined in section 8.4.1.
8.2.3.2 SetTemperature variable 
This variable contains the set temperature to which heating up is to take place and be regulated.
The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.
8.2.3.3 ActualTemperatureChamber_<No.> variable 
The numbered variable ActualTemperaturChamber_<No.> contains the current temperature of a cooking chamber. This variable may be used several times (numbered consecutively), depending on the number of cooking chambers that exist.
The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.
8.2.3.4 SetProcessTimeProgram variable 
This variable describes the set process time of the entire cooking program in seconds.
The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.
8.2.3.5 TimeRemainingProgram variable 
This variable describes the remaining process time of the entire cooking program in seconds, i.e. of the current and all subsequent cooking steps.
The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.
8.2.3.6 SetInternalCoreTemperature variable 
This variable describes the set core temperature for the internal core temperature sensor.
The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.
8.2.3.7 ActualInternalCoreTemperature_<No.> variable 
The numbered variable ActualInternalCoreTemperature_<No.> contains the current temperature of an internal core temperature sensor. This variable may be used several times (numbered consecutively), depending on the number of internal core temperature sensors that exist.
The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.
8.2.3.8 SetExternalCoreTemperature variable 
This variable describes the set core temperature for the external core temperature sensor, if the sensor exists.
The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.
8.2.3.9 ActualExternalCoreTemperature_<No.> variable 
The numbered variable ActualExternalCoreTemperatur_<No.> contains the current temperature of an external core temperature sensor. This variable may be used several times (numbered consecutively), depending on the number of external core temperature sensors that exist.
The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.
8.2.3.10 SpecialCookingMode variable 
This variable describes additional cooking methods that do not belong to the standard scope of a combi steamer.
The data type for the SpecialCookingModeEnumeration is defined in 8.4.2.
8.2.3.11 SetProcessTimeStep variable 
This variable describes the set process time of the current cooking step in seconds.
The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.
8.2.3.12 TimeRemainingStep variable 
This variable describes the remaining process time of the current cooking step in seconds.
The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.
8.2.3.13 SetHumidity variable 
This variable describes the set humidity in percent.
The EngineeringUnit property of the AnalogItemType has the value %. The value for the EURange property is device-specific.
8.2.3.14 ActualHumidity variable 
This variable describes the actual humidity in percent.
The EngineeringUnit property of the AnalogItemType has the value %. The value for the EURange property is device-specific.
8.2.3.15 IsDoorOpen variable 
This variable describes whether the door is open.
8.2.3.16 IsEnergySavingActive variable 
This variable describes whether the energy saving mode is active. The heating power is reduced in this mode.
8.2.3.17 IsSteamExhaustSystemActive variable 
This variable describes whether the steam extraction is active.
8.2.3.18 IsLoaActive variable 
This variable describes whether the device, when connected to a power optimisation system (LOA), has received the release for heating. The value applies only to those devices that are equipped with a LOA connection and are connected.