13 Type definitions for Pasta Cooker / Bain Marie ToC Previous Next

13.2 PastaCookerParameterType ToC Previous Next

13.2.3 Description of the object type ToC Previous Next

13.2.3.1 ProgramMode variable ToC

This variable describes the state of the device, e.g. heating up, frying, etc.

The data type for the PastaCookerModeEnumeration is defined in section 13.4.1.

13.2.3.2 CookingLevel variable ToC

This variable describes the cooking level with which heating up is to take place. The value is used only in the Cook and CookSlow ProgramMode.

13.2.3.3 SetTemperature variable ToC

This variable contains the set temperature to which heating up is to take place.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

13.2.3.4 ActualTemperature variable ToC

This variable describes the currently measured temperature.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

13.2.3.5 SetProcessTime variable ToC

This variable describes the set process time in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

13.2.3.6 TimeRemaining variable ToC

This variable describes the remaining process time in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

13.2.3.7 SignalMode variable ToC

This variable describes the state of the signal output. In addition to the on and off states, the “Signal was acknowledged” state is also saved.

The data type for the SignalModeEnumeration is defined in 13.4.2.

Previous Next