12 Type definitions for Multi Function Pan ToC Previous Next

12.2 MultiFunctionPanParameterType ToC Previous Next

12.2.3 Description of the object type ToC Previous Next

12.2.3.1 MultiFunctionPanMode variable ToC

This variable describes the state of the device, e.g. preheating, active, cleaning

The data type for the MultiFunctionPanModeEnumeration is defined in section 12.4.1.

12.2.3.2 SpecialFunctionMode variable ToC

This variable describes special device functions, e.g. pour in water, tilt pot, lift/lower lid.

The data type for the SpecialFunctionModeEnumeration is defined in section 12.4.2.

12.2.3.3 CookingLevel variable ToC

This variable describes the cook/grill/pressure stage with which the process should run. The cooking process takes place with different control values or pressure presets, depending on the stage.

12.2.3.4 SetTemperature variable ToC

This variable contains the set temperature to which heating up is to take place.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

12.2.3.5 ActualTemperatureBottom variable ToC

This variable describes the currently measured bottom temperature in the pot.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

12.2.3.6 ActualTemperatureCup variable ToC

This variable describes the currently measured cup temperature in the pot.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

12.2.3.7 SetProcessTimeProgram variable ToC

This variable describes the set process time of the entire cooking program in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

12.2.3.8 TimeRemainingProgram variable ToC

This variable describes the remaining process time of the entire cooking program in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

12.2.3.9 SetCoreTemperature variable ToC

This variable describes the set core temperature.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

12.2.3.10 ActualCoreTemperature variable ToC

This variable describes the currently measured core temperature.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

12.2.3.11 ActualPressureAbsolute variable ToC

This variable describes the current absolute pressure in the pot.

The EngineeringUnit property of the AnalogItemType has the value mbar. The value for the EURange property is device-specific.

12.2.3.12 SetProcessTimeStep variable ToC

This variable describes the set process time of the current cooking step in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

12.2.3.13 TimeRemainingStep variable ToC

This variable describes the remaining process time of the current cooking step in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

12.2.3.14 SetZoneTemperature_<No.> variable ToC

The numbered variable SetZoneTemperatur_<No.> contains the set temperature of a zone in C. This variable may be used several times (numbered consecutively), depending on the number of zones that exist.

The value applies only to the MultiFunctionPanMode ZoneGrilling

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

12.2.3.15 ActualZoneTemperature_<No.> variable ToC

The numbered variable ActualZoneTemperatur_<No.> contains the current temperature of a zone in C. This variable may be used several times (numbered consecutively), depending on the number of zones that exist.

The value applies only to the MultiFunctionPanMode ZoneGrilling

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

12.2.3.16 IsLidLocked variable ToC

This variable describes whether the lid is locked. The value applies only to devices with a pressure cooking function.

12.2.3.17 IsWithPressure property ToC

This variable describes whether the device has the equipment for pressure cooking.

12.2.3.18 IsWithCleaning property ToC

This variable describes whether the device is equipped with automatic cleaning.

12.2.3.19 IsWithTilting property ToC

This variable describes whether the device has an automatic tilting facility.

12.2.3.20 IsWithLift property ToC

This variable describes whether the device has a lift.

12.2.3.21 IsLidOpen property ToC

This variable describes whether the lid is open.

Previous Next