10 Type definitions for Pressure Cooking Kettle ToC Previous Next

10.2 PressureCookingKettleParameterType ToC Previous Next

10.2.3 Description of the object type ToC Previous Next

10.2.3.1 ProgramMode variable ToC

This variable describes the state of the device, e.g. heating up, frying.

The data type for the PressureCookingKettleModeEnumeration is defined in section 10.4.1.

10.2.3.2 CookingLevel variable ToC

This variable describes the cooking level with which heating up is to take place. The value is used only in the Cook and CookSlow ProgramMode.

10.2.3.3 SetTemperature variable ToC

This variable contains the set temperature to which heating up is to take place.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

10.2.3.4 ActualTemperature variable ToC

This variable describes the currently measured temperature.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

10.2.3.5 SetProcessTime variable ToC

This variable describes the set process time in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

10.2.3.6 TimeRemaining variable ToC

This variable describes the remaining process time in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

10.2.3.7 SetCoreTemperature variable ToC

This variable describes the set core temperature.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

10.2.3.8 ActualCoreTemperature variable ToC

This variable describes the currently measured core temperature.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

10.2.3.9 ActualPressureAbsolute variable ToC

This variable describes the current absolute pressure in the cooking chamber.

The EngineeringUnit property of the AnalogItemType has the value mbar. The value for the EURange property is device-specific.

10.2.3.10 ActualPressureKettle variable ToC

This variable describes the current absolute pressure in the steam chamber.

The EngineeringUnit property of the AnalogItemType has the value mbar. The value for the EURange property is device-specific.

10.2.3.11 SignalMode variable ToC

This variable describes the state of the signal output. In addition to the on and off states, the “Signal was acknowledged” state is also saved.

The data type for the SignalModeEnumeration is defined in 10.4.2.

10.2.3.12 IsLidLocked variable ToC

This variable describes whether the lid is locked.

10.2.3.13 IsSteamActive variable ToC

This variable describes whether the use of low-pressure steam is active.

10.2.3.14 IsOpenExpressActive variable ToC

This variable describes whether the express pressure relief is active.

Previous Next