3 result(s) for PastSpecification Records
-
OPC-30060 – OPC UA for Tobacco Machine Communication8.1.1 OverviewMaterialOutputPoints 0:FolderType O 0:HasComponent Object MaterialRejectionPoints 0:FolderType O 0:HasComponent Object PastSpecificationRecords 0:FolderType O 0:HasComponent Object ProcessControlLoops 0:FolderType O 0:HasComponent Object ProcessItems ... MaterialRejectionPoints folder provides rejection traps where material is discarded from the machine module. PastSpecificationRecords The PastSpecificationRecords folder contains the information about the machine as was operating in a previous period
-
OPC-30060 – OPC UA for Tobacco Machine Communication8.2.1 Overviewmachine module manufacturer will save an object of type MachineModuleHistoricalType to the folder PastSpecificationRecords which is a component of the relevant MachineModule The MachineModuleHistoricalRecordType is formally defined in the following
-
OPC-30060 – OPC UA for Tobacco Machine Communicationmachine module. Prior to that it saves the previous specification into the PastSpecification Records Object of the same machine module. The signature of this Method is specified below. Table