Search
9 result(s) for Operational
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubcurrently paused by a parent component. The parent component is either Disabled or Paused . Operational 2 The PubSub component is operational. Error 3 The PubSub component is in an error ... enabled but currently in the process to execute the steps necessary to enter the Operational state. Figure 22 depicts the PubSub components that have a PubSub state and their parent
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.9.6 MessageReceiveTimeoutbetween two DataSetMessages . The time starts when the state of the DataSetReader changes to Operational . If there is no new DataSetMessage received within this period, the DataSetReader State shall
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.10.2.3 FieldTargetDataTypedefine the override value handling behaviour if the State of the DataSetReader is not Operational or if the corresponding field in the DataSet contains a Bad StatusCode . The handling ... OverrideValueHandling is set to OverrideValue and the State of the DataSetReader is not Operational or if the corresponding field in the DataSet contains a Bad StatusCode . The handling
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.4.6.7 Statusoffline. If IsCyclic is set to TRUE the Publisher only reports while they are Operational . The NextReportTime indicates when the Publisher will send an update. If the Subscriber does
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.5.5 StatusTimestamp . If IsCyclic is set to TRUE the Publisher only reports when it is Operational . The NextReportTime indicates when the Publisher is expected to send an update. If the Subscriber
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.2 Configuration behavioursDisabled and to apply the new configuration settings when the Status is changed to Operational . Therefore write operations to configuration parameters should be rejected with Bad_InvalidState if the Status
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.11.2 PubSubDiagnosticsTypedefined in 6.2.1 changed to Error state StateOperationalByMethod Mandatory Basic Information State changed to Operational state triggered by Enable Method call. StateOperationalByParent Mandatory Basic Information State changed to Operational state ... triggered by an operational parent StateOperationalFromError Mandatory Basic Information State changed from Error to Operational . StatePausedByParent Mandatory Basic Information State changed to Paused state triggered by a paused or disabled
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelFunctionalGroupType O 0:HasComponent Object 5:Diagnostics 5:FunctionalGroupType O 0:HasComponent Object 5:Operational 5:FunctionalGroupType O 3:HasSubFunctionalEntity Object 3:<SubFunctionalEntity> 3:FunctionalEntityType OP ConformanceUnits UAFX ... ControlGroupType that this Folder contains, see 6.5 . The optional OperationalHealth indicates the operational health of the FunctionalEntity . It aggregates the health of its SubFunctionalEntities and the health of ConnectionEndpoints
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelclean-up shall occur. The time delay period starts following a status change from Operational to any other Status . The time delay is reset to its original value when ... Status changes back to Operational . If the time delay expires, this Connection shall be closed as if the CloseConnections Method was called with Remove set to TRUE