Search
5 result(s) for Move Method
-
OPC-30020 – MDIS OPC UA Companion Specification6.6.4 Choke Move MethodChoke Move Method Move Method is used to adjust the opening size in a choke. Signature: Move ( [in] 0:Float Position, [in] 0:Boolean OverrideInterlocks, [in] SEMEnum SEM); Table ... Move Method Arguments( Choke) Argument Description Position A number (in percent) indicating the percent open to be moved to when operated. OverrideInterlocks Boolean indicating if the open or close command
-
OPC-30020 – MDIS OPC UA Companion Specification6.8.4 Valve Move MethodValve Move Method Move Method is used to open or close a valve. Signature Move ( [in] CommandEnum Direction, [in] 0:Boolean OverrideInterlock, [in] SEMEnum SEM, [in] 0:Boolean Signature ... They are described in Table 124 for ease of reference . Comments: The Move Method initiates a move operation. Parameters include opening or closing of the valve, overriding of any interlocks
-
OPC-30020 – MDIS OPC UA Companion Specification6.9.7 SetManual Methoddescribed in Table 124 for ease of reference. Comments The SetManual Method commands the CIMV to move in the specified direction (open or close) the specified delta. Parameters include Direction ... cause damage to the subsea system. Table 67 specifies the AddressSpace representation for the Move Method . Table 67 - SetManual Method AddressSpace Definition Attribute Value BrowseName SetManual References Node Class BrowseName
-
OPC-30020 – MDIS OPC UA Companion Specification14.2.2 ServerSupports the base required aspect of the MDISValveObjectType . This includes position information and the Move Method for basic functionality. The Move Method basic functionality includes Direction , OverrideInterlocks , SEM and ShutdownRequest ... base required aspect of the MDISChokeObjectType . This includes CalculatedPosition information, Moving flag, the Move Method ( ChokeMove Method ), Abort Method ( ChokeAbort Method ), The Move Method basic functionality includes Position , OverrideInterlocks
-
OPC-30020 – MDIS OPC UA Companion Specification14.2.3 ClientUses the base required aspect of the MDISValveObjectType . This includes position information and the Move Method for basic functionality. The Move Method basic functionality includes Direction , OverrideInterlocks , SEM and ShutdownRequest ... This includes CalculatedPosition information, Moving flag, the Move ( ChokeMoveMethod ), Abort ( ChokeAbortMethod ), SetCalculatedPosition ( ChokeSetCalculatedPositionMethod ). The Move Method basic functionality includes Position , OverrideInterlocks and SEM, The SetCalculatedPosition Method basic functionality includes CalculatedPosition