OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>3.3.5 Encoder ObjectEncoder Object An Encoder Object is a part of an Encoder Unit and contains the Process Control Task . The Encoder Object shall comprise the mandatory functionality: Parameters, measuring task
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>3.2.5 EO IO DataData For an Encoder Object (encoder), all Input and Output Data (cyclic transmission
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>3.3.6 Process Control TaskProcess Control Task The Process Control Task is part of an Encoder Object and is the task that takes the measurements and calculates the results (See [ ENCP ], chapter 5.2.4). Telegram
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>4.1.2 Encoder ObjectEncoder Object The main functions of a PROFINET Encoder are defined by the Encoder Object (EO). The general architecture of an Encoder Object is shown in Figure 2 . Figure ... General Encoder Object architecture ([ ENCP ] chapter 5.2.3) As defined in [ ENCP ], the EO shall have the following minimum functionality: Parameters Measuring task IO Data (setpoint values, actual values) Support
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>LatchStart Method as component of EncoderProbeType Object . Support Commissioning Plant operators parameterize the Encoder Object . Providing the SetAxisConfig, SetControlConfig and SetSensorConfig Methods . Enhance Encoder channels with semantic information Plant operators ... store semantic information providing meaningful additional data for their domain for each Encoder Object . Providing the SetApplicationTag Method as component of the EncoderChannelType Object . Obtain and use metadata for measurement
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>type. The "Configuration" sub-aspect contains Objects holding configuration settings of the Encoder Object . There are also Methods available allowing Clients changing certain settings (See chapters ... Probes" sub-aspect gives access to sensor and probe data of the Encoder Object by providing the "Sensor" and "Probe" Objects . These Objects offer Variables
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>NIST_B" Signal Objects represent Standard Signals provided by an Encoder Object . These Standard Signals are linked to their counterpart Variables in the functional aspect of the Information Model
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>Probes" sub-aspect. Figure 12 - Encoder Channel Sensor & Probes The EncoderSensorType Object offers Encoder sensor related Variables. This component of the EncoderChannelType Object also offers Methods for preset ... latch functionality. The EncoderProbesType Object allows access to probe related functionality of the Encoder Object . Each probe is represented by an EncoderProbeType Object . The EncoderProbeType offers Variables and Methods allowing
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>EncoderChannelType The EncoderChannelType is the representation of the Encoder Object . Clients gain access to the Encoder Object's data, properties, error log and configuration settings using an EncoderChannelType Object . Table ... HasComponent Object Logbook LogbookType O 0:HasComponent Object Sensor EncoderSensorType M 0:HasComponent Object Probes EncoderProbesType O 0:GeneratesEvent ObjectType EncoderDiagnosisEventType Conformance Units PNENC Signals PNENC Measurement PNENC Diagnosis Events
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>7.1.1 SetApplicationTag Methodnetwork failure. The EncoderProfileVersion Variable contains the encoder profile version of the Encoder Object the EncoderChannelType Object represents. The EncoderChannelState Variable contains the representation of the G1_ZSW Signal ... Float data type. Configuration The SensorConfig Object contains sensor related configuration settings of the Encoder Object . See section 7.8 for details. The AxisConfig Object contains Encoder axis related configuration settings
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>7.5.1 DeleteLogbook MethodDeleteLogbook Method clears the LogEntries array and resets the fault buffer of the Encoder Object . The security constraints defined in chapter 6.6 apply. Signature DeleteLogbook ( ); The Method Result Codes (defined