Search
3 result(s) for ElementReplace
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelF.3.3.2.4 ElementReplaceF.3.3.2.4 ElementReplace The ConnectionConfigurationSetOperation ElementReplace replaces the ConnectionConfigurationSet in the ConnectionConfigurationSetFolder. The ConnectionManager shall call the CloseConnections Method on all affected AutomationComponents (see 6.2.5 ) with Remove set to TRUE ... contained Connections in the ConnectionConfigurationSet . The operation ElementReplace does not include processing the new ConnectionConfigurationSet . Processing can be triggered either by a Client using the ProcessConnectionConfigurationSets Method
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelnone of the bits are set. The possible element operations are ElementAdd , ElementRemove , and ElementReplace . Only one of the element operation bits shall be set. If more than ... recommended to set all arrays in the DataType to null or empty. ElementReplace 2 If this bit is set, the ConnectionConfigurationSet is replaced in the ConnectionManager configuration. The ConnectionConfigurationSet
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.6 UAFX ConnectionManagerreading and writing the defined File , the CloseAndUpdate Method , including the ElementAdd , ElementRemove and ElementReplace Operations , and all related DataTypes for the File content. Server UAFX ConnectionManager Exposes CCSs Exposes