Search
12 result(s) for AuditEvent
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model9.5 AuditEventTypeClient issuing a write to a Variable , the Server would generate an AuditEvent describing the Variable as the source and the user and Client session as the initiators ... response to an auditable action request. If the action is accepted, then an action AuditEvent is generated and processed by the Server . If the action is not accepted
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space ModelCertificate related Events . This type follows all behaviours of its parent type. This AuditEvent is generated if the HostName in the URL used to connect to the Server
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space ModelCertificate related Events . This type follows all behaviours of its parent type. This AuditEvent is generated if the current time is outside the validity period's start date
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space ModelCertificate related Events . This type follows all behaviours of its parent type. This AuditEvent is generated if the certificate structure is invalid or if the Certificate has an invalid signature
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space ModelCertificate related Events . This type follows all behaviours of its parent type. This AuditEvent is generated if the Certificate is not trusted, that is, if the Issuer Certificate is unknown
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space ModelCertificate related Events . This type follows all behaviours of its parent type. This AuditEvent is generated if a Certificate has been revoked or if the revocation list is not available
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space ModelCertificate related Events . This type follows all behaviours of its parent type. This AuditEvent is generated if a Certificate set of uses does not match the requested
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.32 RequestHeaderaction and from where it was initiated. The auditEntryId is included in the AuditEvent to allow human readers to correlate an Event with the initiating action. More details
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.3 AuditEventTypedefined in 6.4.2 . The BaseEventType Properties are used to describe the source of the AuditEvent. SubTypes of AuditEventType may define the Node to assign to the SourceNode Property ... SourceNode Property shall be set to the Server Node . The SourceName Property for AuditEvent typically provides more information related to the source of the AuditEvents . If the AuditEvent is related
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions4.2 Conditionsthrough a Method call or some Server / vendor - specific means), rather than generating an AuditEvent Notification for each Condition instance being enabled or disabled. For more information, see the definition
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access5.8.1 GeneralClient issuing a write to a Variable , the Server would generate an AuditEvent describing the Variable as the source and the user and Client Session as the initiators
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelProperty shall be the ObjectId of the Server Object . If AutomationComponentLog is supported, this AuditEvent shall set either the ConditionClassType or a ConditionSubClassType to LogEntryConditionClassType , which results in the Audit ... these AuditEvents to LogRecords shall use the AdditionalData field to include fields of the AuditEvent . Subtypes of the AuditEvent will describe in detail which fields shall be mapped