NodeId | ns=1;i=3016 |
NodeClass | DataType |
BrowseName | 1:ExplosionProtectionOptionSet |
DisplayName | ExplosionProtectionOptionSet |
Description | defines flags for the category of explosion protection for devices according to EU Directive 2014/34/EU (ATEX) |
BaseType | 0:OptionSet |
IsAbstract | False |
Name | Bit No | Description |
---|---|---|
M1 | 0 | This category is intended for use in underground mines and their surface installations which may be endangered by firedamp and/or combustible dust. Category 1 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a very high level of safety. (2014/34/EU) |
M2 | 1 | This category is intended for use in underground mines and their surface installations which may be endangered by firedamp and/or combustible dust. Category 2 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a high level of safety. (2014/34/EU) |
1G | 2 | Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and gases, vapours or mists is present. Category 1 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a very high level of safety. (2014/34/EU) |
2G | 3 | Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and gases, vapours or mists is present. Category 2 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a high level of safety. (2014/34/EU) |
3G | 4 | Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and gases, vapours or mists is present. Category 3 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a normal level of safety. (2014/34/EU) |
1D | 5 | Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and dust is present. Category 1 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a very high level of safety. (2014/34/EU) |
2D | 6 | Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and dust is present. Category 2 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a high level of safety. (2014/34/EU) |
3D | 7 | Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and dust is present. Category 3 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a normal level of safety. (2014/34/EU) |
Reference | NodeClass | BrowseName | TypeDefinition | DataType | Other |
---|---|---|---|---|---|
0:HasProperty | Variable | 0:OptionSetValues | 0:PropertyType | 0:LocalizedText[8] | M |