SwitchToEnergySavingMode
http://opcfoundation.org/UA/PNEM/
1.0.0
2021-03-11
NodeId | ns=1;i=7007 |
NodeClass | Method |
BrowseName | 1:SwitchToEnergySavingMode |
DisplayName | SwitchToEnergySavingMode |
Parent | 1:EnergyStandbyManagementType |
Name | DataType | Description | |
---|---|---|---|
ModeID | [in] | 0:Byte | ID of the requested energy saving mode. |
EffectiveModeID | [out] | 0:Byte | ID of the effectively chosen destination energy saving mode if successful, otherwise current mode. |
CurrentTimeToDestination | [out] | 0:Duration | Time needed to reach the destination energy saving mode if successful, otherwise unchanged. |
RegularTimeToOperate | [out] | 0:Duration | Time needed to reach PE_ready_to_operate again if the destination energy saving mode will be regularly terminated if successful, otherwise unchanged. |
TimeMinLengthOfStay | [out] | 0:Duration | Time of minimum stay in the destination energy saving mode if successful, otherwise unchanged. |
ReturnCode | [out] | 0:Byte | Return code. See table Table 11. |
Reference | NodeClass | BrowseName | TypeDefinition | DataType | Other |
---|---|---|---|---|---|
0:HasProperty | Variable | 0:InputArguments | 0:PropertyType | 0:Argument[1] | M |
0:HasProperty | Variable | 0:OutputArguments | 0:PropertyType | 0:Argument[5] | M |