OperatingModeEnumeration

http://opcfoundation.org/UA/PlasticsRubber/TCD/

1.01

2020-06-01


NodeId ns=1;i=3002
NodeClass DataType
BrowseName 1:OperatingModeEnumeration
DisplayName OperatingModeEnumeration
Description Actual operating mode of the TCD
BaseType 0:Enumeration
IsAbstract False
Name Value Description
OTHER 0 Operating mode of the TCD is unknown
READY_TO_OPERATE 1 TCD is ready to operate (heating, pump and cooling are switched off)
NORMAL_OPERATION 2 TCD is running in normal operating mode
LEAK_STOPPER 3 TCD is running in leak stopper operating mode
MOULD_EVACUATION 4 TCD is carrying out a mould evacuation process
PRESSURE_RELIEF 5 TCD is carrying out a pressure relief process
COOLING 6 TCD is cooling down to StandbyTemperature and switch off
SAFETY_COOLING 7 TCD is cooling down to SwitchingOffTemperature and switch off
ECO 8 TCD is running in Eco operating mode (energy is saved via the reduced pump speed)
BOOST 9 TCD is running in Boost operating mode (pump runs at maximum possible speed)
Reference NodeClass BrowseName TypeDefinition DataType Other
0:HasProperty Variable 0:EnumValues 0:PropertyType 0:EnumValueType[10] M