SystemStateDataType

http://opcfoundation.org/UA/MachineVision

1.0.0

2019-07-11


NodeId ns=1;i=3023
NodeClass DataType
BrowseName 1:SystemStateDataType
DisplayName SystemStateDataType
BaseType 0:Enumeration
IsAbstract False
Name Value Description
PRD_1 1 Production: The vision system is currently working on a job.
SBY_2 2 Stand by: The vision system is ready to accept a command but is currently not executing a job. It could for example be waiting for a Start command or a user input.
ENG_3 3 Engineering: The vision system is not working and not ready to accept a command because a user is currently working on the system. This could be for editing a recipe or changing the system configuration.
SDT_4 4 Scheduled downtime: The vision system is not available for production and this was planned in advance. This could be for cleaning, maintenance or calibration works.
UDT_5 5 Unscheduled downtime: The vision system is not available for production due to failure and repair. This covers all kinds of error states that might occur during operation.
NST_6 6 Nonscheduled time: The vision system is not working because no production was scheduled. This also covers things like operator training on the system.
Reference NodeClass BrowseName TypeDefinition DataType Other
0:HasProperty Variable 0:EnumValues 0:PropertyType 0:EnumValueType[6] M