EDMGeneratorState

http://opcfoundation.org/UA/MachineTool/

1.01.1

2022-07-04


NodeId ns=1;i=71
NodeClass DataType
BrowseName 1:EDMGeneratorState
DisplayName EDMGeneratorState
BaseType 0:Enumeration
IsAbstract False
Name Value Description
Undefined 0 The EDM spark generator state cannot be indicated.
Ready 1 Generator is initialized and can receive a set of technology parameters.
Active_Low_Voltage 2 Generator is switched on and is supplying pulses respecting the low voltage (≤ 25 V AC or ≤ 60 V DC) requirements of safety standard (ISO 28881).
Active_High_Voltage 3 Generator is switched on and is supplying pulse at high voltage (> 25 V AC or > 60 V DC).
Error 4 Generator is in an error state.
Reference NodeClass BrowseName TypeDefinition DataType Other