OPC Foundation
  • Documents
  • NodeSets
  • Search
10.1 ExchangeablePartDataType

This structure contains properties that are used to identify an exchangeable part inside or on the device. Exchangeable parts can be measurement equipment such as load cells and clamp types or tear and wear parts such as jaw faces.

The structure is defined in Table 40.

Table 40 – ExchangeablePartDataType Structure

Name

Type

Description

Optional

ExchangeablePartDataType

structure

Subtype of 0:Structure defined in OPC 10000-5

PartType

0:String

Name of the machine part.

False

Mounted

0:Boolean

Flag stating if the part is currently mounted or not.

False

Traceable

0:Boolean

Flag stating if the part is traceable (e.g. has an Id or serial number).

True

PartId

0:String

Id or serial number of the part.

True

MachineReadable

0:Boolean

Flag stating if the PartId is machine readable.

True

LastCalibrationDate

0:UtcTime

Date of the last calibration of this part if available.

True

Its representation in the AddressSpace is defined in Table 41.

Table 41 – ExchangeablePartDataType Definition

Attribute

Value

BrowseName

ExchangeablePartDataType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:Structure defined in OPC 10000-5

Conformance Units

TTD_TextileTestingDeviceType

Please report errors or issues with the site to webmaster.

Copyright © 2025 - OPC Foundation