OPC Foundation
  • Documents
  • NodeSets
  • Search
6.19.20 IntegrityRejectedMaterialLogType

The IntegrityRejectedMaterialLogType Event is triggered when a presented material is rejected at an object of type MaterialLoadingPointType because of a failed material integrity check.

Table 70 – IntegrityRejectedMaterialLogType Definition

Attribute

Value

BrowseName

IntegrityRejectedMaterial LogType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Modelling Rule

Subtype of LogbookEventType

HasComponent

Variable

RejectedLot

Double

MaterialLotType

Mandatory

The MaterialLotType VariableType is defined in 8.3.

The RejectedLot Variable describes the presented lot of material that did not pass the integrity check.