6.19.7 GoodOutputProducedLogType

When the MasterTotalOutput of a MaterialOutput Object of a MachineModule increases its value, the GoodOutputProduced LogType is fired.

Table 57 – GoodOutputProducedLogType Definition

Attribute

Value

BrowseName

GoodOutputProducedLogType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Modelling Rule

Subtype of LogbookEventType

HasProperty

Variable

QuantityProduced

Double

MaterialLotType

Optional

HasProperty

Variable

TotalProduced

Double

MaterialLotType

Mandatory

The MaterialLotType Variable Type is defined in Table 75.

The QuantityProduced Variable represents the quantity of material produced and the type of material produced. It is Optional.

The TotalProduced Variable represents the total quantity of material produced as in MasterTotalOutput (see 6.12.4.5) and the type of material produced. It is Optional.