Table 182 contains the defined NotificationCategories which can be used for classification of the alarms or events.
Table 182 – Defined NotificationCategories
Name |
ValueAsText |
EnumValue |
Description |
Others |
OTHERS |
0 |
Notifications that are not related to another class |
Process |
PROCESS |
1 |
Notification that are related to the weighing or value-added process |
System |
SYSTEM |
2 |
Notifications that are related to scale system, like date errors or hardware errors |
Memory |
MEMORY |
3 |
Notification that are related to the memory. |
Component |
COMPONENT |
4 |
Notifications that are related a component of the scale |
Communication |
COMMUNICATION |
5 |
Notification that are related a communication system like a field bus error |
WeighingBridgeModule |
WEIGHING_MODULE |
6 |
Notifications that are related to the weighingBridgeModule |
Environment |
ENVIRONMENT |
7 |
Notification that are related to the environment |
Table 183 contains the defined NotificationIds.
Table 183 – Defined NotificationIds
NotificationId - ValueAsText |
NotificationId - EnumValue |
NotificationCategory |
Description |
NotificationIds that are not related to another class |
|||
GENERAL_OTHER_FAULT |
1 |
OTHERS |
A general fault that not related to another NotificationCategory |
NotificationIds related to the Process |
|||
GENERAL_PROCESS_FAULT |
100 |
PROCESS |
A general fault that is related to the process. This fault should be used if no other fault related to the process exist. |
PRODUCT_DATA_FAULT |
101 |
PROCESS |
Inconsistent or incomplete product data |
LABEL_FAULT |
102 |
PROCESS |
General label error, limited only to the label |
BAD_PACK |
103 |
PROCESS |
Package sorted out |
CRITICAL_EXTERNAL_FAULT |
104 |
PROCESS |
Critical Alarm from external Device (like metal detector, external storage etc.) |
REJECT_VERIFICATION_FAULT |
105 |
PROCESS |
Item reject process not successful |
CONTAMINATION_DETECT |
106 |
PROCESS |
Machine rejects due to a detected contamination (x-ray / MD) |
VISION_INSPECTION |
107 |
PROCESS |
Machine rejects due to a wrong vision of code inspection |
CONSECUTIVE_REJECTS |
108 |
PROCESS |
Machine stop due to consecutive rejects |
EMERGENCY_STOP |
109 |
PROCESS |
Emergency stop is active and not acknowledged yet |
NotificationIds related to the System |
|||
GENERAL_SYSTEM_FAULT |
200 |
SYSTEM |
A general fault that is related to the system. This fault should be used if no other fault related to the system exist |
LOGIN_FAULT |
201 |
SYSTEM |
Unsuccessful login event |
NotificationIds related to the Memory |
GENERAL_MEMORY_FAULT |
300 |
MEMORY |
A general fault that is related to the memory |
NotificationIds related to the Component of a scale |
|||
GENERAL_COMPONENT_FAULT |
400 |
COMPONENT |
A general fault that is related to the component of a system. This fault should be used if no other fault related to the component exist |
PRINTER_FAULT |
401 |
COMPONENT |
General printer fault, which prevents at least one printer from printing |
FEEDER_FAULT |
402 |
COMPONENT |
General Feeder error, but feeder is running yet |
FEEDER_NOT_RUNNING |
403 |
COMPONENT |
Special Alarm to indicate "feeder not running" state |
NotificationIds related to the Communication of a scale |
|||
GENERAL_COMMUNICATION_FAULT |
500 |
COMMUNICATION |
A general fault that is related to the communication system. This fault should be used if no other fault related to the communication exist |
NotificationIds related to the weighing module |
|||
GENERAL_WEIGHING_MODULE_FAULT |
600 |
WEIGHING_MODULE |
A general fault that is related to the weighing module This fault should be used if no other fault related to the weighing module exist |
OVERLOAD_FAULT |
601 |
WEIGHING_MODULE |
Scale overloaded. That means the maximum allowed measured weight value is exceeded and the Overload property of a WeightItemType is true. |
OUT_OF_RANGE_FAULT |
602 |
WEIGHING_MODULE |
Weight out of (approved) range, but not yet overload |
UNDERLOAD_FAULT |
603 |
WEIGHING_MODULE |
Scale underloaded. That means the minimum allowed measured weight value is gone below. |
TARE_SETTING_FAULT |
604 |
WEIGHING_MODULE |
Error during tare setting |
ZERO_SETTING_FAULT |
605 |
WEIGHING_MODULE |
Error during zero setting |
REZERO_REQUIRED |
606 |
WEIGHING_MODULE |
Load cell re-zeroing is required |
NotificationIds related to the Environment |
|||
GENERAL_ENVIRONMENT_FAULT |
700 |
ENVIRONMENT |
A general fault that is related to the environment system. This fault should be used if no other fault related to the environment exist |
POWER_SUPPLY_FAULT |
701 |
ENVIRONMENT |
General faulty power supply |
AIR_PRESSURE_FAULT |
702 |
ENVIRONMENT |
General faulty air pressure |