Table 18 shows the definition of the RequestSPDUDataType. The Prefix “In” is interpreted from the SafetyProvider’s point of view and is used in a consistent manner to the parameters of the Method ReadSafetyData (see 6.2.2.3).
Table 18 – RequestSPDUDataType structure
Name |
Type |
Description |
RequestSPDUDataType |
structure |
|
InSafetyConsumerID |
UInt32 |
|
InMonitoringNumber |
UInt32 |
|
InFlags |
InFlagsType |
The representation in the AddressSpace of the RequestSPDUDataType is defined in Table 19.
Table 19 – RequestSPDUDataType definition
Attributes |
Value |
||||
BrowseName |
RequestSPDUDataType |
||||
IsAbstract |
False |
||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
ModellingRule |
Subtype of Structure defined in OPC 10000-3. |
|||||
Conformance units |
|||||
SafetyPDUs |