6.2.3.1 InFlagsType

The InFlagsType a subtype of the Byte DataType with the OptionSetValues Property defined. The InFlagsType is formally defined in Table 14.

CommunicationError can be used as a trigger, e.g. for a communication analysis tool. It is not forwarded to the safety application by the SafetyProvider. If CommunicationError is necessary in the safety application, bidirectional communication can be implemented and the value of CommunicationError can be put into the user data.

Table 14 – InFlagsType values

Value

Bit no.

Description

CommunicationError

0

0: No error

1: An error was detected in the previous ResponseSPDU.

OperatorAckRequested

1

Used to inform the SafetyProvider that operator acknowledgment is requested.

FSV_Activated

2

Used for conformance test of SafetyConsumer.SAPI.FSV_Activated.

Bits 3 to 7 are reserved for future use and shall be set to zero by the SafetyConsumer. They shall not be evaluated by the SafetyProvider.

The InFlagsType representation in the AddressSpace is defined in Table 15.

Table 15 – InFlagsType dDefinition

Attribute

Value

BrowseName

InFlagsType

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of the Byte DataType defined in OPC 10000-3

0:HasProperty

Variable

0:OptionSetValues

0:LocalizedText []

0:PropertyType

Conformance units

SafetySupport

Please report errors or issues with the site to webmaster.