The OPC UA ReferenceType IsDrivenBy is used to describe dependencies between objects which have a driving or powering character. The BrowseName IsDrivenBy and the InverseName Drives describe semantically the hierarchical dependency.
Example for usage in this companion specification: an electrical motor IsDrivenBy and servo amplifier (drive) and an internal drive of a motion device or a drive as a component of a controller Drives a motor.
The SourceNode of this type shall be an ObjectType or Object and the TargetNode shall be an Object.
Table 109 – Drives Reference Definition
|
Attributes |
Value |
||||
|
BrowseName |
IsDrivenBy |
||||
|
InverseName |
Drives |
||||
|
Symmetric |
False |
||||
|
IsAbstract |
False |
||||
|
Subtype of the HierarchicalReferences defined in OPC Unified Architecture Part 5 |
|||||
|
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
ModellingRule |