OPC Foundation
  • Documents
  • NodeSets
  • Search
7.45 OutletConnectionSystemRequirementsType ObjectType Definition

The OutletConnectionSystemRequirementsType provides static Variables for Pump outlet connection specific parameters of the process in which the Pump is to be used and is formally defined in Table 98.

Table 98 – OutletConnectionSystemRequirementsType Definition

Attribute

Value

BrowseName

OutletConnectionSystemRequirementsType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node.

0:HasComponent

Variable

BackingPressure

0:Double

0:BaseAnalogType

O, RW

The InstanceDeclarations of the OutletConnectionSystemRequirementsType have additional Attributes defined in Table 99. The Variables and the associated Descriptions are based on the standard DIN ISO 21360-1.

Table 99 – OutletConnectionSystemRequirementsType Attribute values for child Nodes

BrowsePath

Value Attribute

Description Attribute

BackingPressure

Pressure at the outlet of a vacuum pump.

BackingPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

Please report errors or issues with the site to webmaster.