OPC Foundation
  • Documents
  • NodeSets
  • Search
7.4.10 PtAssetOutputFilterType ObjectType Definition
7.4.10.1 Overview

The PtAssetOutputFilterType describes an output filter in a powertrain and is formally defined in Table 46. The output filter is intended to be placed on the motor side of the PTS, after the converter or output converter. Its purpose is to suppress converter harmonics from entering the motor. The PtAssetOutputFilterType is a subtype of the PtAssetType and therefore has mandatory identification attributes and optional asset attributes of PtCommonAssetAttributesType.

Table 46 – PtAssetOutputFilterType Definition

Attribute

Value

BrowseName

PtAssetOutputFilterType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of the PtAssetType defined in chapter 7.1

HasPtAttributes

Object

PtOutputFilterAttributes

PtOutputFilterAttributesType

M

HasPtAttributes

Object

PtReactorAttributes

PtReactorAttributesType

O

HasPtAttributes

Object

PtOutputInterfaceAttributes

PtOutputInterfaceAttributesType

O

Conformance Units

Powertrain Base System

Powertrain Asset Identification

Powertrain Asset Identification Writable Tag

Powertrain Asset Attributes Types

Powertrain Attributes Information

7.4.10.2 Object Description

PtOutputFilterAttributes are formally defined in chapter 7.9.8.

PtReactorAttributes are formally defined in chapter 7.9.5.

PtOutputInterfaceAttributes are formally defined in chapter 7.11.14.

Please report errors or issues with the site to webmaster.