MeasuringRange provides the measurement range between the minimum and maximum value. The unit shall be millimeters per square second [mm/s2].

FrequencyRange provides the frequency range between the minimum and maximum value. The unit shall be hertz [Hz].

DigitalInputElectricalType describes the supported digital electrical type of the sensor input. The values of the MultiStateValueDiscreteType variable are defined in Table 94 and shall be used. The values 0-199 are reserved for future extensions of this specification. The values 200-299 shall be used for vendor-specific extensions of this variable.

Table 94 – PtVibrationSensorAttributesType Attribute values for child Nodes

BrowsePath

Value Attribute

Description Attribute

DigitalInputElectricalType

0:EnumValues

[ { "Value": 0, "DisplayName": "TTL", "Description": "Transistor-transistor logic (0..5 V)" }, { "Value": 1, "DisplayName": "HTL", "Description": "High threshold logic (0..24 V)" }, { "Value": 2, "DisplayName": "PNP", "Description": "PNP transistor type" }, { "Value": 3, "DisplayName": "NPN", "Description": "NPN transistor type" }, { "Value": 4, "DisplayName": "CONFIGURABLE", "Description": "Configurable" }, { "Value": 5, "DisplayName": "PULSE_TRAIN", "Description": "Pulse train" }, { "Value": 6, "DisplayName": "RELAY", "Description": "Electromechanical relay" } ]

DigitalOutputElectricalType

0:EnumValues

[ { "Value": 0, "DisplayName": "TTL", "Description": "Transistor-transistor logic (0..5 V)" }, { "Value": 1, "DisplayName": "HTL", "Description": "High threshold logic (0..24 V)" }, { "Value": 2, "DisplayName": "PNP", "Description": "PNP transistor type" }, { "Value": 3, "DisplayName": "NPN", "Description": "NPN transistor type" }, { "Value": 4, "DisplayName": "CONFIGURABLE", "Description": "Configurable" }, { "Value": 5, "DisplayName": "PULSE_TRAIN", "Description": "Pulse train" }, { "Value": 6, "DisplayName": "RELAY", "Description": "Electromechanical relay" } ]

AnalogInputElectricalType

0:EnumValues

[ { "Value": 0, "DisplayName": "VOLTAGE_0-10V", "Description": "Voltage range 0-10 volt" }, { "Value": 1, "DisplayName": "VOLTAGE_-10-10V", "Description": "Voltage range -10-10 volt" }, { "Value": 2, "DisplayName": "CURRENT_0-20MA", "Description": "Current range 0-20 milliampere" }, { "Value": 3, "DisplayName": "CURRENT_4-20MA", "Description": "Current range 4-20 milliampere" }, { "Value": 4, "DisplayName": "TEMPERATURE_PT1000", "Description": "PT1000 temperature sensor" }, { "Value": 5, "DisplayName": "TEMPERATURE_PT100", "Description": "PT100 temperature sensor" }, { "Value": 6, "DisplayName": "TEMPERATURE_KTY", "Description": "KTY temperature sensor" }, { "Value": 7, "DisplayName": "TEMPERATURE_KTY84", "Description": "KTY84 temperature sensor" }, { "Value": 8, "DisplayName": "TEMPERATURE_PTC", "Description": "PTC temperature sensor" }, { "Value": 9, "DisplayName": "VOLTAGE", "Description": "Other voltage interface" }, { "Value": 10, "DisplayName": "CURRENT", "Description": "Other current interface" }, { "Value": 11, "DisplayName": "TEMPERATURE", "Description": "Other temperature interface" }, { "Value": 12, "DisplayName": "CONFIGURABLE", "Description": "Configurable" } ]

AnalogOutputElectricalType

0:EnumValues

[ { "Value": 0, "DisplayName": "VOLTAGE_0-10V", "Description": "Voltage range 0-10 volt" }, { "Value": 1, "DisplayName": "VOLTAGE_-10-10V", "Description": "Voltage range -10-10 volt" }, { "Value": 2, "DisplayName": "CURRENT_0-20MA", "Description": "Current range 0-20 milliampere" }, { "Value": 3, "DisplayName": "CURRENT_4-20MA", "Description": "Current range 4-20 milliampere" }, { "Value": 4, "DisplayName": "TEMPERATURE_PT1000", "Description": "PT1000 temperature sensor" }, { "Value": 5, "DisplayName": "TEMPERATURE_PT100", "Description": "PT100 temperature sensor" }, { "Value": 6, "DisplayName": "TEMPERATURE_KTY", "Description": "KTY temperature sensor" }, { "Value": 7, "DisplayName": "TEMPERATURE_KTY84", "Description": "KTY84 temperature sensor" }, { "Value": 8, "DisplayName": "TEMPERATURE_PTC", "Description": "PTC temperature sensor" }, { "Value": 9, "DisplayName": "VOLTAGE", "Description": "Other voltage interface" }, { "Value": 10, "DisplayName": "CURRENT", "Description": "Other current interface" }, { "Value": 11, "DisplayName": "TEMPERATURE", "Description": "Other temperature interface" }, { "Value": 12, "DisplayName": "CONFIGURABLE", "Description": "Configurable" } ]

OutputFunction

0:EnumValues

[ { "Value": 0, "DisplayName": "ACTIVE_OPEN", "Description": "Active function signal by open output" }, { "Value": 1, "DisplayName": "ACTIVE_CLOSED", "Description": "Active function signal by closed output" } ]

DigitalOutputElectricalType describes the supported digital electrical type of the sensor output. he values of the MultiStateValueDiscreteType variable are defined in Table 94and shall be used. The values 0-199 are reserved for future extensions of this specification. The values 200-299 shall be used for vendor-specific extensions of this variable.

AnalogInputElectricalType describes the supported analog electrical type of the sensor input. The values of the MultiStateValueDiscreteType variable are defined in Table 94and shall be used. The values 0-199 are reserved for future extensions of this specification. The values 200-299 shall be used for vendor-specific extensions of this variable.

AnalogOutputElectricalType describes the supported analog electrical type of the sensor output. The values of the MultiStateValueDiscreteType variable are defined in Table 94 and shall be used. The values 0-199 are reserved for future extensions of this specification. The values 200-299 shall be used for vendor-specific extensions of this variable.

OutputFunction provides if the output is normally open or normally closed. he values of the MultiStateValueDiscreteType variable are defined in Table 94and shall be used. The values 0-199 are reserved for future extensions of this specification. The values 200-299 shall be used for vendor-specific extensions of this variable.

Accuracy provides the accuracy of the measured acceleration value. The unit shall be millimeters per square second [mm/s2].

Linearity provides an expression of the extent to which the actual measured curve of the vibration sensor departs from the ideal curve. The unit shall be percent [%].

OperatingVoltage specifies the operating voltage range of the vibration sensor. The unit shall be volt [V].

Resolution of the sensor with regards to voltage output in relationship to acceleration input. The unit shall be millivolts per meters per square second [mV/mm/s2].

The attributes of the PtVibrationSensorAttributesType have additional sub-attributes which are defined in Table 95.

Table 95 – PtVibrationSensorAttributesType additional subattributes

BrowsePath

References

NodeClass

BrowseName

DataType

TypeDefinition

Others

MeasuringRange

0:HasProperty

Variable

0:EngineeringUnits

EUInformation

0:PropertyType

M

FrequencyRange

0:HasProperty

Variable

0:EngineeringUnits

EUInformation

0:PropertyType

M