9 OperationType

9.6 OperatingMode

Description: Actual operating mode of the TCD.
Table 6 – OperatingModeEnumeration Values
Name | Value | Description |
---|---|---|
OTHER | 0 | Operating mode of the TCD is unknown |
READY_TO_OPERATE | 1 | TCD is ready to operate (heating, pump and cooling are switched off) |
NORMAL_OPERATION | 2 | TCD is running in normal operating mode |
LEAK_STOPPER | 3 | TCD is running in leak stopper operating mode |
MOULD_EVACUATION | 4 | TCD is carrying out a mould evacuation process |
PRESSURE_RELIEF | 5 | TCD is carrying out a pressure relief process |
COOLING | 6 | TCD is cooling down to StandbyTemperature and switch off |
SAFETY_COOLING | 7 | TCD is cooling down to SwitchingOffTemperature and switch off |
ECO | 8 | TCD is running in Eco operating mode (energy is saved via the reduced pump speed) |
BOOST | 9 | TCD is running in Boost operating mode (pump runs at maximum possible speed) |