This chapter defines the corresponding Conformance Unit for OPC 40082-3.
Table 27 – Conformance Units for OPC 40082-3
Category |
Title |
Description |
Server |
OPC 40082-3 Basic |
Support of LDS_InterfaceType and all mandatory child elements giving information on the LDS and its status. There is at least one instance of the LDS_InterfaceType in the Machines Object. |
Server |
OPC 40082-3 Alarms |
Support of HelpOffNormalAlarmType, ComponentAlarmType and AdditiveAlarmType providing error information. If this facet is supported and a client subscribes to the events, the server shall provide all errors via alarms in addition to the error variables included in the OperationType |
Server |
OPC 40083 Tolerances |
Support of Status, UpperTolerance and LowerTolerance in the MonitoredParameterType and ControlledParameterType and the according alarms. |
Server |
OPC 40082-3 DosingFunction |
Support of StartDosing, StopDosing and DosingActive in the OperationType |
Server |
OPC 40082-3 Purge |
Support of PurgeMode, PurgeStatus, PurgeQuantitiy and PurgeTimeout in the OperationType |
Server |
OPC 40082-3 PurgeCyclic |
Support of OPC 40082-3 Purge, the PurgeMode CYCLIC_COMPONENT_A_B and PurgeCyclicQuanitity, PurgeCyclicIdleTime, PurgeCyclicActive in the OperationType |
Server |
OPC 40082-3 SelectableMaterialBalanceSystem |
If SELECTABLE is supported in the MaterialBalanceSystemTypeEnumeration, the variable AcivateMaterialBalanceSystem has to be supported. |
Server |
OPC 40082-3 DeliveryPressure |
If DeliveryType PRESSURE is supported, DeliveryPressure and DeliveryPressureMeasuringPoint have to be supported |
Server |
OPC 40082-3 Flowrate |
If DeliveryType VOLUMETRIC_FLOWRATE is supported, DeliveryFlowRate has to be supported |
Server |
OPC 40082-3 MixingRatioTarget |
If a Material balance system is used, MixingRatioTarget has to be supported |
Server |
OPC 40082-3 BalanceSystem |
If a Material balance system is used, MaxDeviationMixingRatio, TargetDeviationMixingRatio, ActualDeviationMixingRatio have to be supported. |
Server |
OPC 40082-3 Identify Device |
Support of the IdentifyDevice Method in the OperationType |
Server |
OPC 40082-3 ResetAllErrors |
Support of the ResetAllErrors Method in the OperationType |
Server |
OPC 40082-3 ResetErrorById |
Support of the ResetErrorById Method in the OperationType |
Server |
OPC 40082-3 SetCycleNumber |
Support of the SetCycleNumber Method in the OperationType |
Server |
OPC 40082-3 ActualShotWeight |
Support of the ActualShotWeight Variable in the OperationType |
Server |
OPC 40082-3 SetShotWeight |
Support of the SetShotWeight Variable in the OperationType |
Server |
OPC 40082-3 SetValueCompositeDensity |
Support of the SetValueCompositeDensity Variable in the OperationType |
Server |
OPC 40082-3 RemainingMaterialTime |
Support of the RemainingMaterialTime Variable in the OperationType |
Server |
OPC 40082-3 Additive |
Support of the AdditiveType with all its mandatory child elements |
Server |
OPC 40082-3 SetValueDensity |
Support of the SetValueDensity Variable in the ComponentType |
Server |
OPC 40082-3 SetSetValueDensity |
Support of the SetSetValueDensity Method and the SetValueDensity Variable in the ComponentType |
Server |
OPC 40082-3 ActualPressure |
Support of the ActualPressure Variable in the ComponentType |
Server |
OPC 40082-3 ActualFollowerPlatePressure |
Support of the ActualFollowerPlatePressure Variable in the ComponentType |
Server |
OPC 40082-3 SetFollowerPlatePressure |
Support of the SetFollowerPlatePressure Variable in the ComponentType |
Server |
OPC 40082-3 DrumCapacity |
Support of the DrumCapacity Variable in the ComponentType |
Server |
OPC 40082-3 ResidualAmount |
Support of the ResidualAmount Variable in the ComponentType |
Server |
OPC 40082-3 RemainingMaterialTime |
Support of the RemainingMaterialTime Variable in the ComponentType |
Server |
OPC 40082-3 AllowsCycles |
Support of the AllowsCycle Variable in the ComponentType |
Server |
OPC 40082-3 AdditiveFraction |
Support of AdditiveFraction in the AdditiveType |
Server |
OPC 40082-3 AdditiveStrokeVolume |
Support of AdditiveStrokeVolume in the AdditiveType |
Server |
OPC 40082-3 AdditiveClosedLoopControl |
Support of ActivateClosedLoopControl and ClosedLoopControlActivated in the AdditiveType |